<strong>ITALY</strong> - 4 Wastewater<br />

Notes:<br />

Microbiological<br />

parameters<br />

Parameter Unit<br />

Applicable limit<br />

for irrigation<br />

and civil uses (10)<br />

Applicable limit<br />

for industrial<br />

uses (9)<br />

Oil and Grease mg/L 10 20<br />

Mineral oil mg/L 0.05 (6) --<br />

Total Phenols mg/L 0.1 0.5<br />

Pentachlorophenol mg/L 0.003 --<br />

Total Aldehydes mg/L 0.5 1<br />

Tetrachloroethylene,<br />

Trichloroethylene -<br />

Sum of the<br />

concentration of the<br />

specific parameters.<br />

mg/L 0.01 --<br />

Chlorinated Solvents mg/L 0.004 1<br />

Trihalomethane - Sum<br />

of the concentration<br />

mg/L 0.003 --<br />

Total Aromatic Organic<br />

Solvents<br />

mg/L 0.01 0.2<br />

Benzene mg/L 0.001 --<br />

Benzo[a]pyrene mg/L 0.00001 --<br />

Total Nitrated Organic<br />

Solvents<br />

mg/L 0.01 0.1<br />

Total Surfactants mg/L 0.5 2<br />

Chlorinated<br />

Pesticides(each)<br />

mg/L 0.0001 (7) --<br />

Phosphorated<br />

Pesticides (each)<br />

mg/L 0.0001 0.1<br />

Total Pesticides<br />

(excluding<br />

phosphorated<br />

pesticides)<br />

mg/L 0.05 0.05<br />

Escherichia coli UFC/10 10 (80% of total<br />

0 ml samples) (8)<br />

max 5,000 (4)<br />

Acute Toxicity test -- 50% survival (5)<br />

Salmonella Absent (14) --<br />

(1) For watercourses, the maximum variation from the average temperature of any section upstream or downstream<br />

of the discharge point shall not exceed 3°C. On at least half of any downstream section of the discharge point,<br />

the variation shall not exceed 1°C.<br />

For lakes, the discharge temperature shall not exceed 30°C, while the temperature increase of the receiving<br />

water body shall not exceed 3°C at a distance of 50 meters from the discharge point.<br />

For artificial canals, the maximum average value of water temperature in any section shall not exceed 35°C.<br />

This condition is subject to the approval of the canals’ administrator.<br />

For sea and outlet zones of non-significant streams, the discharge temperature shall not exceed 35°C, and the<br />

temperature increase of the receiving water body shall not exceed 3°C at a distance of 1,000 meters from the<br />

discharge point. The environmental compatibility of the discharge with the receiving body shall be ensured, and<br />

the formation of thermal barriers shall be avoided at river outlets.<br />

(2) For urban wastewater discharge limits see Table 4.1 third column.<br />