14.06.2013 Views

ENVIRONMENTAL FINAL GOVERNING STANDARDS ITALY

ENVIRONMENTAL FINAL GOVERNING STANDARDS ITALY

ENVIRONMENTAL FINAL GOVERNING STANDARDS ITALY

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>ITALY</strong> - 3 Drinking Water<br />

Table 3.9. Radionuclide MCLs and Monitoring Requirements<br />

Contaminant MCL<br />

Gross Alpha 1,5 15 pCi/L<br />

Combined Radium-226 and -228 5 5 pCi/L<br />

Beta Particle and Photon Radioactivity 2, 5 4 mrem/yr<br />

Uranium 5 30 µg/L<br />

Tritium 4 100 Bequerel/L<br />

Total Indicative Dose 3, 4 0.10 MSv/year<br />

Notes:<br />

1. Gross alpha activity includes radium-226, but excludes radon and uranium.<br />

2. Beta particle and photon activity is also referred to as gross beta activity from manmade radionuclides.<br />

3. Excluding tritium, potassium-40, radon and radon decay products.<br />

4. Monitoring frequencies and analytical methods have not been set yet.<br />

5. The monitoring requirements for Gross Alpha, Combined Radium-226 and -228, Beta Particle and Photon<br />

Radioactivity, and Uranium apply to CWS only.<br />

Monitoring Requirements:<br />

All installations using ground water, surface water, or systems using both ground and surface water must sample at<br />

every point (i.e., sampling points) to the distribution system that is representative of all sources being used under<br />

normal operating conditions. 5<br />

For gross alpha activity and radium-226 and radium-228, systems will be tested once every 4 years. Testing will be<br />

conducted using an annual composite of 4 consecutive quarterly samples or the average of four samples obtained at<br />

quarterly intervals at a representative point in the distribution system.<br />

Gross alpha only may be analyzed if activity is ≤5 picoCuries per liter (pCi/L). Where radium-228 may be present,<br />

radium-226 and/or -228 analyses should be performed when activity is >2 pCi/L. If the average annual concentration<br />

is less than half the MCL, analysis of a single sample may be substituted for the quarterly sampling procedure. A<br />

system with two or more sources having different concentrations of radioactivity shall monitor source water in<br />

addition to water from a free-flowing tap. If the installation introduces a new water source, these contaminants will<br />

be monitored within the first year after introduction.<br />

September 2012 Italy FGS 3-34<br />

Revision 0

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!