LCO 3.0.6<br />

(cont.)<br />

Calibration that requires removal <strong>of</strong> equipment from service does not constitute<br />

failure to meet an LCO if individual calibration procedures describe appropriate<br />

limitation beyond which an OUT-OF-TOLERANCE CONDITION would exist.<br />

If such limitations are not described in the individual calibration procedures, a<br />

planned OUT-OF-TOLERANCE shall be declared before removing equipment<br />

from service for calibration.<br />

If an installed indicator is reading as expected and within required parameters,<br />

but is found to be past due for calibration during the interval between required<br />

SURVEILLANCES, and redundant indication is not available, declaring the<br />

applicable LCO not met may be delayed for up to 24 hours, or the interval <strong>of</strong> the<br />

SURVEILLANCE, whichever is shorter, from the time it is DISCOVERED that<br />

the indicator is past due for calibration. This delay period is permitted to allow<br />

the installation <strong>of</strong> a calibrated substitute or to calibrate the installed indicator,<br />

which allows validation <strong>of</strong> the actual operating parameter. The failure <strong>of</strong> a<br />

calibration requires that the affected SAFETY SSC be declared OUT-OF-<br />

TOLERANCE, and the LCO REQUIRED ACTIONS taken, as the minimum<br />

requirements described for the associated LCO that cannot be met. Reporting <strong>of</strong><br />

the failed calibration is required in accordance with contractor procedures.<br />

If the in-calibration indicator reading is not taken within the delay period, the<br />

LCO shall not met, and the COMPLETION TIMES <strong>of</strong> the REQUIRED<br />

ACTIONS for the applicable LCO CONDITIONS shall begin immediately upon<br />

expiration <strong>of</strong> the delay period. If the in-calibration indicator reading is outside<br />

required parameters within the delay period, the LCO shall not be met and the<br />

applicable REQUIRED ACTIONS shall be entered. The COMPLETION TIMES<br />

<strong>of</strong> the REQUIRED ACTIONS begin immediately upon observing the<br />

unsatisfactory reading with an in-calibration indicator.<br />

LCO 3.0.7 Performing SURVEILI&VCE REQUIREMENTS<br />

Revision 1<br />

.September 1993<br />

An SR inspection or test that requires removal <strong>of</strong> equipment from service or that<br />

causes an LCO specification to be exceeded does not constitute failure to meet an<br />

LCO provided that individual work control documents implementing these<br />

inspections or tests describe appropriate limitations beyond which an<br />

OUT-OF-TOLERANCE CONDITION would exist.<br />

Failing an LCO-required SR requires the system component to be deemed not<br />

OPERABLE and the appropriate REQulRED ACTIONS be taken.<br />

If it is determined that LCO-required equipment is not OPERABLE during the<br />

performance <strong>of</strong> an inspection or test, the appropriate REQUlRED ACTIONS<br />

shall be taken.<br />

A-20<br />

Building 991 Complex FSAR<br />

Appendix A<br />