AOL 4 The quantities <strong>of</strong> radioactive material in LLW drums and LLW crates received<br />

at and stored in the BUILDING 991 COMPLEX shall not exceed 0.5 grams<br />

Weapons Grade Plutonium equivalent and 3 grams Weapons Grade Plutonium<br />

equivalent, respectively.<br />

The quantities <strong>of</strong> radioactive material in TRU waste drums and TRU waste<br />

crates received at and stored in the BUILDING 991 COMPLEX shall not exceed<br />

200 grams Weapons Grade Plutonium equivalent and 320 grams Weapons<br />

Grade Plutonium equivalent, respectively.<br />

The quantities <strong>of</strong> radioactive material in POC containers received at and stored<br />

in the BUILDING 991 COMPLEX shall not exceed either 1,255 grams Weapons<br />

Grade Plutonium equivalent or 200 grams (or Criticality Safety approved<br />

amount) fissionable material.<br />

All POC and waste containers received at the BUILDING 991 COMPLEX docks<br />

shall be verified to be compliant with this requirement either before shipment to the<br />

BUILDING 99 1 COMPLEX or at receipt.<br />

'APPLICABIL,ITY: At all times in the BUILDING 991 COMPLEX.<br />

ACTIONS:<br />

CONDITION<br />

inventory requirement when<br />

received.<br />

Revision 1<br />

Sc3tcmher 1.994<br />

REQUIRED ACTION<br />

1. Terminate all container movements in the<br />

vicinity <strong>of</strong> the non-compliant container.<br />

- AND<br />

2.<br />

Contact Criticality Safety to determine if<br />

the container is infracted if greater than<br />

200 grams fissionable material.<br />

- AND<br />

3. Remove the non-compliant container<br />

from the BUILDING 991 COMPLEX<br />

A-86<br />

COMPLETION<br />

TIME<br />

10 minutes.<br />

2 hours.<br />

If the container is not<br />

infiacted, withhi<br />

24 holm.<br />

OR<br />

K the container is<br />

infracted, per<br />

direction <strong>of</strong><br />

Criticality Safety.<br />

Building 991 Complex FSAR<br />

Appendis A<br />

I