<strong>Fire</strong> Protection<br />

Causes and prevention of fi re<br />

Have measures been taken <strong>to</strong> ensure the early installation and operation of:<br />

– escape stairs (including compartment walls)? <br />

– lightning conduc<strong>to</strong>rs? <br />

– au<strong>to</strong>matic fi re alarms? <br />

– au<strong>to</strong>matic sprinkler systems? <br />

– hose reels? <br />

Are fi re dampers and fi re s<strong>to</strong>pping provided at the earliest opportunity? <br />

Is steelwork protected as soon as possible? <br />

Are adequate water supplies available for fi re fi ghting purposes? <br />

Are all hydrants clear of obstruction? <br />

Portable <strong>Fire</strong> Extinguishers<br />

Are adequate numbers of suitable extinguishers provided? <br />

Are suffi cient personnel trained in their use? <br />

Are extinguishers located in conspicuous positions near exits? <br />

Are carbon dioxide extinguishers in place adjacent <strong>to</strong> electrical equipment? <br />

Do all mechanically propelled site plant carry suitable extinguishers? <br />

Have procedures been implemented for the regular inspection and maintenance<br />

of extinguishers? <br />

Site Security against Arson<br />

Are adequate areas of the site, including all s<strong>to</strong>rage areas, protected by hoarding? <br />

Is security lighting installed? <br />

Has closed circuit television (CCTV) been installed? <br />

If CCTV is in position are the screens moni<strong>to</strong>red and/or recorded? <br />

Is the site checked for hazards at the end of each work period, particularly<br />

where hot work has been in progress? <br />

Temporary Buildings<br />

Has the contrac<strong>to</strong>r made application for a fi re certifi cate (if applicable)? <br />

Is the fi rebreak between the temporary building and the structure undergoing work<br />

more than 10 metres? <br />

If the fi rebreak is les than 6 metres:<br />

– is the temporary building constructed with materials which will not signifi cantly<br />

contribute <strong>to</strong> the growth of fi re? <br />

– is the building fi tted with an au<strong>to</strong>matic fi re detection system? <br />

Recommendations<br />

171