4.2.4.10.2 Datalogger display<br />

The data recorded in a datalogger channel is displayed as a display function of a display element,<br />

whereby the data values are shown as a continuous characteristic curve in a value-time<br />

diagram.<br />

picture 31: Datalogger display in a display element as a value-time diagram<br />

To configure a datalogger display, a display element (23) must be first added to a page created<br />

in the ETS plug-in by the project planer. This element should then be configured as a "datalogger<br />

display" (see chapter 4.2.4.2.2. Display elements).<br />

Up to two datalogger channels can be displayed as curves (24) & (25) in a diagram (display element).<br />

The curves to be displayed are selected using the parameters "Curve 1: datalogger<br />

channel" and "Curve 2: datalogger channel". Within a datalogger display element, only those<br />

channels with the same recording periods can be displayed.<br />

i The diagram size is directly affected by the size of the display element. Here, the minimum<br />

size should be maintained, according to the information shown and the scaling of the axes.<br />

If the minimum size is undershot, then it will not be possible to show the diagram on the<br />

panel display. In this case, the appropriate display element is filled with a cross.<br />

The Y axis (26) can be scaled dynamically according to the values to be displayed (specified by<br />

minimum and maximum values of the recording period) or, alternatively, can be permanently<br />

configured in a value range. If the scaling of the Y axis is fixed, and there is a data value outside<br />

the specified minimum or maximum limits, then the data value curve is drawn in vertically upwards<br />

or downwards from the two neighbouring data points.<br />

The scaling of the X axis is automatically specified by the configured recording period and the<br />

resulting time intervals of a datalogger channel. At the bottom left side of the X axis, the diagram<br />

always displays the time of the measured value of the first successfully evaluated interval<br />

of the previous recording period (27). The data value curve begins at this time. The bottom right<br />

item of the X axis displays the time at which the measured value of the last interval of the recording<br />

period was recorded (29). If only one interval was recorded, then the two displayed<br />

times are the same.<br />

The formatting of the date and time is specified in the top parameter node of the plug-in using<br />

the "Date display format" and "Time display format" parameters. The data - partially with special<br />

formatting - is only displayed for recording periods lasting several days, weeks or months. The<br />

time is only displayed on the X axis when the recording period is set to "Hour" or "Day".<br />

Both axes can be given subdivisions (29) and additional lines (30) to simplify the legibility of the<br />

diagrams.<br />

In the parameter group of the datalogger display, it is possible to configure a heading for the<br />

diagram (31) and names for each curve (32). In addition, "reinforcement" and "offset" can be<br />

Order-No. 7574 00 1X<br />

Software "...590101"<br />

Functional description<br />