Request date / time No<br />

Yes<br />

Request by 0 telegram<br />

1 telegram<br />

Comparison with external<br />

clock<br />

h Download behaviour<br />

Overwrite light scene<br />

names, delete values<br />

Order-No. 7574 00 1X<br />

No<br />

Date & time<br />

Date<br />

Time<br />

No<br />

Yes<br />

Software "...590101"<br />

Parameters<br />

time change" objects transmits a single<br />

read request to the bus (status poll object<br />

flag = yes).<br />

The effect of the "No" setting is that the<br />

panel does not automatically switch from<br />

summer to winter time, for example, because<br />

a higher-level clock has already<br />

transmitted appropriately corrected date<br />

and time information.<br />

The panel can use the "Request date /<br />

time" object to transmit an enquiry telegram<br />

to the bus, in order to synchronise<br />

the internal clock. In the "Yes" setting,<br />

this communication object transmits a<br />

request telegram after each device initialisation<br />

and then regularly once a day<br />

at 4:00 a.m.. The response of the current<br />

time and date is then expected via<br />

the objects "<strong>Master</strong>Date" and "<strong>Master</strong>-<br />

Time".<br />

This parameter defines the telegram polarity<br />

of the telegram which the panel<br />

transmits to the bus as a synchronisation<br />

request. This parameter is only visible<br />

on "Request date / time = Yes".<br />

If a higher-level clock (master clock) regularly<br />

transmits the current time and / or<br />

the current date, the panel can synchronise<br />

the internal clock automatically<br />

using telegrams from the higher-level<br />

clock. In this case, the "<strong>Master</strong>Time and<br />

<strong>Master</strong>Date" objects can be shown according<br />

to the setting of this parameter.<br />

This parameter is only visible on "Request<br />

date / time = No".<br />

After commissioning, the operator can<br />

make various settings directly on the<br />

panel while the system is running.<br />

These also include the names and settings<br />

of light scenes. During first commissioning<br />

of a device with new project<br />

planning data, these parts must be overwritten.<br />

For this, set the parameter<br />

"Overwrite light scene name, clear values"<br />

to "Yes". After first download, the<br />

parameter can be reset to "No" to maintain<br />

any changes made by the user in<br />

subsequent programming operations.<br />