Order-No. 7574 00 1X<br />

picture 39: System page for mailboxes<br />

(41) Display name of a mailbox (specified in the PC Client software)<br />

(42) "Letter icon" to signal new e-mails in the mailbox<br />

A button is displayed in the mailbox overview for each active e-mail in the PC Client software<br />

(see chapter 4.3.1. Introduction, installation and program start). The display name of each mailbox,<br />

as entered in the PC Client software, appears as text in the buttons (41) and thus clearly<br />

identifies the mailboxes. Mailboxes with new messages are indicated by a "letter icon" (42).<br />

As soon as the operator taps a mailbox button, the panel switches to the inbox display page of<br />

the appropriate mailbox (see picture 40).<br />

i Pressing a mailbox button for a long time (> 5 s) synchronises the appropriate mailbox with<br />

the mail server. This allows manual synchronisation in addition to the cyclic mailbox polling<br />

by the panel.<br />

It should be noted that the synchronisation operation may take several seconds. For this<br />

reason, it is necessary to wait after manual synchronisation until the inbox is opened.<br />

i Optionally, each mailbox and the main e-mail page "Mailboxes" can be protected by passwords.<br />

Should password protection be required, then the password levels of the panel must<br />

be assigned in the "e-mail" parameter node in the ETS plug-in. If a mailbox is protected by<br />

a password, then the display page of the inbox (see picture 40) is only displayed if the<br />

password was input correctly.<br />

The passwords can be set using the "Adjust passwords" system page (Service page -><br />

Area 3 -> Passwords).<br />

i If the panel could not synchronise the mailboxes (e.g. connection fault in the network /<br />

there has been no synchronisation on the mail server or after a device reset), then the panel<br />

confirm the operation in the negative with an acoustic tone when the mailbox button is<br />

tapped. In this case, the panel does not switched to the inbox display page.<br />

(43) Message header of the e-mail<br />

picture 40: Inbox display page of a mailbox<br />

Software "...590101"<br />

Functional description<br />

Page 129 of 222