Curve 1 / 2:<br />

Offset<br />

Y axis:<br />

Display axis title<br />

Y axis<br />

Axis title<br />

Y axis: automatic scaling<br />

Order-No. 7574 00 1X<br />

the diagram.<br />

i In a diagram, the values of a datalogger<br />

channel are displayed,<br />

without reformatting, in the way that<br />

they are receive in the data telegram<br />

from the bus, providing that<br />

no reinforcement or offset is specified<br />

in the configuration of the<br />

curve. As a result, a data value, for<br />

example, received in the format<br />

DPT 5,001 (1 byte value) in a value<br />

range of 0...255 can be displayed in<br />

the diagram. If, in this example, percentage<br />

values should be displayed<br />

(e.g. command values), the data<br />

values can be reformatted by the<br />

reinforcement. In such a case, a 1<br />

byte data value (0...255) with a reinforcement<br />

of "0.392" can be converted<br />

to a percentage data value<br />

(0...100 %).<br />

0 A static offset can be added to the<br />

measured values of a channel to allow<br />

the option of modification to the desired<br />

measured value ranges in the diagram.<br />

An offset not equal to "0" shifts the curve<br />

along the Y axis in a positive or negative<br />

direction.<br />

Yes<br />

No<br />

The Y axis of the graphic display can be<br />

overwritten with a text. This parameter<br />

defines whether the text heading of the<br />

Y axis should be displayed in the display<br />

element.<br />

[Y axis] The Y axis title is specified here. This<br />

parameter is only visible when the axis<br />

title of the Y axis is to be displayed.<br />

Yes<br />

No<br />

Software "...590101"<br />

Parameters<br />

The Y axis can be scaled automatically<br />

according to the values to be displayed<br />

(specified by minimum and maximum<br />

values of the recording period / "Yes"<br />

setting) or, alternatively, can be permanently<br />

configured in a value range<br />

("No" setting). If the scaling of the Y axis<br />

is fixed, and there is a data value outside<br />

the specified minimum or maximum<br />

limits, then the data value curve is<br />

drawn in vertically upwards or downwards<br />

from the two neighbouring data<br />

points.<br />