Order-No. 7574 00 1X<br />

picture 33: Page for selecting the channel of the presence simulation.<br />

Software "...590101"<br />

Functional description<br />

At this point, the user sees the 32 functions (recording objects) created in the ETS plug-in. The<br />

user can now select up to 15 functions and include them in the presence simulation. The selections<br />

are made directly by tapping the appropriate function button on the screen. A function selected<br />

for the presence simulation is indicated by an "X" in the function button behind the function<br />

designation. Tapping the function button again deselects the function. In the same way, the<br />

state "Selected" or "Not selected" can be influenced using the "Activate / Deactivate" button.<br />

After pressing the "Save back" button, the selection is saved in the panel and the panel jumps<br />

back to the system page of the presence simulation. Pressing the "Cancel back" button simply<br />

causes a jump back to the presence simulation page without saving the user configuration.<br />

By changing the channel selection, the user can, at any time, change the functions included in<br />

the presence simulation and, if the situation requires, adapt it to special requirements.<br />

i The channel selection is only saved temporarily in the RAM of the panel, meaning that a<br />

new selection is required (every function deactivated) and resaving is required after a<br />

power failure or a programming operation.<br />

i If the function selection is changed and resaved after a simulation has been recorded, then<br />

the previous recording is deleted. The operator must then record a new simulation (see<br />

next section).<br />

Recording a telegram sequence<br />

After the operator has selected the functions of the presence simulation, the telegram sequence<br />

can be recorded. For this, the operator must first specify a maximum recording period in days.<br />

Usually, a simulation recording takes place independently in the background. The length of the<br />

recording period can be used to specify when the simulation recording stops automatically after<br />

starting. Independently of this, a recording can also be stopped manually at any time (see below).<br />

The length of the recording period can be edited using the on-screen numeric keyboard after<br />

tapping the "Length:..." button. Periods of 1 ... 7 days can be configured.<br />

A day is not a calendar day but a 24 hour period. Example: if the recording begins on Tuesday<br />

at 9:00, the first day of the recording will end on Wednesday at 8:59. The start time of the recording<br />

thus specifies the start of a day, i.e. of a 24 hour period.<br />

Before starting recording, ensure that the time and weekday on the panel is set correctly!<br />