For "Blind" display function...<br />

Status display As text<br />

As icon<br />

Order-No. 7574 00 1X<br />

The display element can display either<br />

texts of status images from the image<br />

list to display the status.<br />

Image text for blind up [Up] Here, the text can be entered to be displayed<br />

in the display element on the<br />

status "Blind up".<br />

This parameter is only visible with<br />

"Status display = as text".<br />

Image text for blind<br />

down<br />

[Down] Here, the text can be entered to be displayed<br />

in the display element on the<br />

status "Blind down".<br />

This parameter is only visible with<br />

"Status display = as text".<br />

Icon for blind up No presetting Here, an icon can be configured using<br />

the image list to be displayed in the display<br />

element on the status "Blind up".<br />

This parameter is only visible with<br />

"Status display = as icon".<br />

Icon for blind down No presetting Here, an icon can be configured using<br />

the image list to be displayed in the display<br />

element on the status "Blind down".<br />

This parameter is only visible with<br />

"Status display = as icon".<br />

Time base between<br />

short/long-time operation<br />

Time factor between<br />

short/long-time operation<br />

10 ms<br />

100 ms<br />

1 s<br />

Software "...590101"<br />

Parameters<br />

This parameter specifies the time base<br />

for the time from which the panel detects<br />

long actuation. For improved accuracy,<br />

we recommend selecting a small time<br />

base with a large time factor.<br />

This parameter only has a function when<br />

the function "Blind function of the display<br />

element" has been selected for function<br />

button 1.<br />

0...3...127 This parameter specifies the time factor<br />

for the time from which the panel detects<br />

long actuation. For improved accuracy,<br />

we recommend selecting a small time<br />

base with a large time factor.<br />

This parameter only has a function when<br />

the function "Blind function of the display<br />

element" has been selected for function<br />

button 1.<br />