Curve 1 / 2:<br />

Datalogger channel<br />

Curve 1 / 2:<br />

Name<br />

Curve 1 / 2:<br />

Curve type<br />

Curve 1 / 2:<br />

Amplification<br />

Order-No. 7574 00 1X<br />

---<br />

...<br />

Selection list of the datalogger<br />

channels of the same<br />

recording periods<br />

ger channels in curve format. Each<br />

curve is displayed in its own colour. This<br />

parameter enables the legend display,<br />

thus displaying the curve names (separately<br />

configurable) on the bottom edge<br />

of the display element, which are assigned<br />

to the curve colours. This allows<br />

better identification of the curves.<br />

The datalogger channel to be display is<br />

selected here. In a display element, only<br />

those channels with the same recording<br />

periods can be displayed.<br />

For a selection to be possible here, at<br />

least one datalogger channel must have<br />

been added in the "Datalogger" parameter<br />

group in advance.<br />

[Curve] A name for the curve of the appropriate<br />

datalogger channel can be entered here.<br />

This name is displayed in the legend of<br />

the display element. The legend must<br />

then be enabled using the "Display legend"<br />

parameter.<br />

Min<br />

Average value<br />

Max<br />

Software "...590101"<br />

Parameters<br />

Telegrams reaching the communication<br />

object of a datalogger channel are divided<br />

up within a recording period to<br />

various time intervals and assigned to<br />

them. At the end of each time period,<br />

the telegrams received are evaluated<br />

and a minimum and maximum interval<br />

value determined. In addition, an average<br />

value is calculated and saved. The<br />

smallest and largest values are evaluated<br />

as the minimum and maximum values.<br />

To calculate the average, the recorded<br />

values are totalled and divided by<br />

the number of recorded values. If, within<br />

a time period, only one telegram data<br />

value was received, then the minimum<br />

value = maximum value = average<br />

value.<br />

This parameter specifies which recorded<br />

data value is to be displayed in the diagram<br />

as the "curve type" (maximum<br />

value, minimum value or average value).<br />

When a datalogger channel is displayed<br />

with differentials in the data value recording,<br />

it is not possible to select the<br />

curve type as there can only be one differential<br />

value displayed for each interval.<br />

1 Reinforcement (multiplicator) can be added<br />

to the measured values of a channel<br />

to allow the option of modification to<br />

the desired measured value ranges in<br />