4-June-07 P1901_PRO_016_r0<br />

- Destination Port 0 to 7 – 8x7 bits. Local Port of the intended receiver of the Data Token. If Destination Port<br />

X is not used, it shall be set to 0. At least one of the destination ports shall be different to 0.<br />

The implementation of this type of token is optional.<br />

7<br />

Always MUST be<br />

set to 0<br />

Always MUST be<br />

set to 0<br />

6<br />

Type<br />

Single Validity<br />

Always MUST be<br />

set to 0<br />

Always MUST be<br />

set to 0<br />

Always MUST be set to 0<br />

Always MUST be<br />

set to 0<br />

Always MUST be<br />

set to 0<br />

Always MUST be<br />

set to 0<br />

Always MUST be<br />

set to 0<br />

4.4.2.10 Clock Token<br />

The Clock Token has the following fields:<br />

5<br />

4<br />

5F<br />

73<br />

EE<br />

E2<br />

Submission page 126 UPA-OPERA<br />

3<br />

Destination Port 0<br />

Validity [7:0]<br />

Destination Port 1<br />

Always MUST be set to 0<br />

2<br />

Validity [11:8]<br />

Destination Port 2<br />

Destination Port 3<br />

Unused Frame Symbols [12:8]<br />

Unused Frame Symbols [7:0]<br />

Destination Port 4<br />

Destination Port 5<br />

Destination Port 6<br />

Destination Port 7<br />

Always MUST be set to 0<br />

Always MUST be set to 0<br />

Always MUST be set to 0<br />

Always MUST be set to 0<br />

Always MUST be set to 0<br />

Figure 49 Non-returnable Data Token<br />

- Preamble – 32 bits. The preamble is equal to 0x5F73EEE2.<br />

- Type – 4 bits. Type shall be CLOCK (3)<br />

- Reset – 1 bit. If set to 1 all nodes reset the timers <strong>and</strong> data.<br />

- Grid Frequency – 2 bits: 00 = 50 Hz , 01= 60Hz, 11 = Other.<br />

1<br />

0<br />

preamble<br />

- MaximumlTimerValue – 16 bits: number of cycles of a 312.5 kHz clock used by the Master to count 9