Jan. 1, 2002 P. 15<br />

ESD and Latch-up Data<br />

Device Latch-Up Human Body Model Charge Device Model<br />

XC17XXD/L +/- 300 mA +2000V to +4000V +2000V (1)<br />

XC17XXE, XC17SXX +/- 300 mA +2000V to +4000V +1000V (8)<br />

XC18VXX +/- 250 mA +2000V +500V (9)<br />

XC31XX/A +/- 250 mA +1750V to +8000V +1000V (3)<br />

XC3XXX/A +/- 220 mA +4000V to +7000V +2000V (2)<br />

XC4XXX/A +/- 300 mA +1000V to +8000V +2000V (4)<br />

XC4XXXE +/- 250 mA +3000V to +8000V +2000V (5)<br />

XC4XXXEX +/- 250 mA +3000V to +7000V +2000V (6)<br />

XC4XXXXL +/- 250 mA +2000V to +8000V +1000V (7)<br />

XC4XXXXLA +/- 260 mA +2000V to +7000V +500V(Core)/ +1000V(corner)(10)<br />

®