Jan. 1, 2002<br />

P. 5<br />

2.1 Wafer Process Qualification<br />

<strong>Reliability</strong> Test Condition Duration<br />

High Temperature<br />

Operating Life (HTOL)<br />

Temperature Humidity<br />

Bias (THB) or<br />

High Accelerated stress<br />

Test (HAST)<br />

Temperature Cycling<br />

(TC)<br />

High Temperature<br />

Storage (HTS) C<br />

Data RetentionD Program EraseC,D Note:<br />

Ta >/=125°C,<br />

V DD Max<br />

85°C, 85% R.H.,<br />

V DD or<br />

130°C, 85% R.H.,<br />

V DD<br />

Lot<br />

Qty<br />

SS/lot A Acceptance<br />

1,000 hours 3 76 0 fail<br />

1,000 hours<br />

or<br />

100 hours<br />

2 76 0 fail<br />

-65°C/+150°C or<br />

-55°C/+125°C B<br />

500 cycles or 1 76 0 fail<br />

1,000 cycles<br />

Ta = 150°C 1,000 hours 1 76 0 fail<br />

Ta = 150°C 1,000 hours 1 76 0 fail<br />

Ta = 75°C 10,000 cycles 1 76 0 fail<br />

A. The sample size listed is based on the die size