CHAPTER 5: <strong>MOSAIQ</strong> <strong>Radiation</strong> <strong>Oncology</strong> Clinical Charting<br />

3. Type the number of the treatment field in the first Field text box.<br />

4. Type the name of the treatment field in the second Field text box.<br />

5. Click adjacent to the Machine field, then double-click the linear accelerator used to<br />

treat the patient with the field.<br />

6. Click adjacent to the Tolerance field, then select the tolerance table for the anatomical<br />

area to treat.<br />

This defines the degree of tolerance within which the treatment unit parameters must<br />

remain when setting up the patient.<br />

7. Type the dose in Dose field.<br />

Dosimetry lets you calculate dose site coefficients and define the dose<br />

contributions from each applicable prescription site.<br />

8. Click adjacent to the Type field, then select the type of beam.<br />

9. Click adjacent to the Modality field, then select the method of treatment.<br />

10. In the Beam Configuration dialog box, select the Mv in the Energy column, select the<br />

dose rate in the Doserate column, then click OK.<br />

The energy and dose rate options that appear are defined in the machine characterization<br />

of the selected linear accelerator. If an energy level or doserate was not defined in the<br />

machine characterization, it does not appear in the Beam Configuration dialog box.<br />

11. In the Treatment Field Definition dialog box, type the monitor units in the MU field.<br />

The Wedge MU field is only significant for sites with Elekta or GE<br />

linear accelerators. If you have a Varian or Siemens linear<br />

accelerator, never use the Wedge MU field.<br />

12. Type the treatment delivery time in the Time field.<br />

Manually Creating Accessory Information<br />

You can specify parameters for accessories such as wedges, compensators, and blocks.<br />

If you choose electrons for the treatment modality, the Applicator<br />

field appears instead of the Wedge field. The drop-down list shows<br />

cones for the selected machine.<br />

1. In the Wedge group of the Treatment Field Definition dialog box, click adjacent to<br />

the Wedge field, then select the wedge to be used in treatment.<br />

2. Type the name of the compensator required for treatment in the Compensator field.<br />

Copyright 2010, Elekta Impac Software 93<br />

LUGMSQ0002/4.0/23-Sep-2010