<strong>MOSAIQ</strong> User’s <strong>Guide</strong><br />

Overrides<br />

The Site Setup Verification window shows all the parameter mismatches in red color. A<br />

mismatch occurs when the actual value of a parameter is either out of tolerance or is not an<br />

exact match to its prescribed value. The Overrides window lets you to clear all the parameter<br />

mismatches to continue with the current treatment workflow.<br />

CAUTION<br />

To override a parameter mismatch, you must have Clinical | Tx<br />

Delivery | Approve rights.<br />

1. In the Site Setup Verification window, click Override to open the Overrides window.<br />

The Override Parameters group shows all parameters that you can override.<br />

2. Click the parameter check box or press SPACEBAR for the highlighted selection to<br />

override the parameter that is out of tolerance.<br />

3. Type your notes in the Note group.<br />

4. In the Override Approval group, the logged in user name appears by default. Type your<br />

password, then click OK.<br />

5. Click Close to close the Overrides window.<br />

Treatment Delivery<br />

Field Sequencing<br />

<strong>MOSAIQ</strong> lets you sequence treatment fields on the Treatment Calendar (refer to, Scheduling<br />

AFS Sessions and Scheduling MFS Treatment Sessions in Chapter 4 on pages 122. You can<br />

configure Automated Field Sequences (AFS) and Manual Field Sequences (MFS).<br />

Automatic Field Sequences and Manual Field Sequences<br />

The Treatment Delivery Table dialog box shows AFS or MFS sequences. Each field that is<br />

part of a sequence shows the current field number in the sequence and the total number of<br />

fields in the sequence. When multi-segmented IMRT fields are part of an AFS, each segment<br />

in the treatment field becomes a single segment in the overall sequence. If you change a field<br />

in an AFS from the Treatment Delivery Table, then the AFS sequence becomes invalid for<br />

that session. You can treat the fields in the sequence as non-sequenced fields in the session.<br />

Select the first field in the sequence to start an AFS or MFS sequence treatment. If you do not<br />

select the first field in an AFS sequence, <strong>MOSAIQ</strong> shows a "Treat Sequence Out of Order?"<br />

message. If you click Yes, then the Verified Treatment window opens for that field. If you<br />

treat the field, then the AFS sequence becomes invalid for that session. You can treat the<br />

remaining fields in the sequence as non-sequenced fields in the session.<br />

270 Copyright 2010, Elekta Impac Software<br />