<strong>MOSAIQ</strong> User’s <strong>Guide</strong><br />

Scanning Simulation Films<br />

CAUTION<br />

Before beginning, make sure you configure the applicable settings in<br />

the DFI Configuration dialog box.<br />

You must power on the scanner before you power on your <strong>MOSAIQ</strong><br />

workstation. If you fail to do so, <strong>MOSAIQ</strong> will not detect the scanner.<br />

1. Click File | Import/Export | Digitized Film Import to open the Digitize Film Import<br />

dialog box.<br />

The Status field shows Waiting for film. The other scanning statuses are as follows:<br />

"Waiting for film" when no film is loaded.<br />

"Digitizer not ready..." when a film is loaded and while the digitizer performs<br />

Automatic Digitizer Calibration (ADC).<br />

"Digitizing…" while the film is being digitized.<br />

"Processing image…" after the film has been digitized and while the image is being<br />

processed.<br />

"Done" when image processing is complete and a thumbnail of the image is<br />

displayed.<br />

"Ready to digitize" when digitizing is complete and another film is loaded.<br />

"Saving image…" while writing the image file.<br />

"Image saved" when the image file is written to the staging area.<br />

2. Click adjacent to the Machine field, then click the machine used to create the image<br />

on the simulator film.<br />

If the film was acquired on a machine in your department and you configured default<br />

settings for that machine, the default Film Information settings for the machine<br />

automatically appear when you select the machine name.<br />

3. Verify or type the source-to-axis distance in the SAD field, press TAB, then verify or type<br />

the source-to-film Distance in the SFD field.<br />

This specifies image distances for specific planes so that measurements may be made<br />

from ViewStation. You bypassed the Pixel Size Type field to accept the default, SFD. Use<br />

SFD for standard films taken from a simulator or accelerator. You select Actual when<br />

you do not know the SFD.<br />

4. Click adjacent to the Image type field, then click the type of image.<br />

144 Copyright 2010, Elekta Impac Software<br />

LUGMSQ0002/4.0/23-Sep-2010