12.07.2015 Views

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3-36 Programming and ParametersFileGroupNameNo. DescriptionValues227 753 Dig Out SetpointDigital Output SetpointControls Relay or Transistor Outputs when chosen as the source. Can be used to control outputs from a communication device using DataLinks.Read-WriteData TypeOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedTrans Out 0Relay Out 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition TrueFEEDB<strong>AC</strong>K & I/ODigital Outputs230 753 RO0 SelDefault: 0RW 32-bitRelay Output 0 SelectMin/Max: 0 / 159999.15IntegerSelects the source that will energize the relay output.Any status parameter bit can be used as an output source. For example P935[Drive Status 1] bit 7 “Faulted”.231 753 RO0 Level SelDefault: 0RW 32-bitRelay Output 0 Level SelectMin/Max: 0 / 159999IntegerSelects the source of the level that will be compared.232 753 RO0 LevelDefault: 0.0RW RealRelay Output 0 LevelSets the level compare value.Min/Max: –/+1000000.0233 753 RO0 Lvl CmpStsRelay Output 0 Level Compensation StatusStatus of the level compare, and a possible source for a relay or transistor output. Relay Output X Select or Transistor Output X Select must have thisselected to energize the output. Can be used without a physical output as status information only.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedGrt Than EquLess ThanDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition True234 753 RO0 On TimeRelay Output 0 On TimeSets the “ON Delay” time for the digital outputs. This is the time between theoccurrence of a condition and activation of the relay.235 753 RO0 Off TimeRelay Output 0 Off TimeSets the “OFF Delay” time for the digital outputs. This is the time between thedisappearance of a condition and de-activation of the relay.240 753 TO0 SelTransistor Output 0 SelectSelects the source that will energize the relay or transistor output.Any status parameter bit can be used as an output source. For example P935[Drive Status 1] bit 7 “Faulted”.241 753 TO0 Level SelTransistor Output 0 Level SelectSelects the source of the level that will be compared.242 753 TO0 LevelTransistor Output 0 LevelSets the level compare value.Units: SecsDefault: 0.00Min/Max: 0.00 / 600.00Units: SecsDefault: 0.00Min/Max: 0.00 / 600.00Default: 0Min/Max: 0 / 159999.15Default: 0Min/Max: 0 / 159999Default: 0.0Min/Max: –/+1000000.0RW RealRW RealRW 32-bitIntegerRW 32-bitIntegerRW Real<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!