Programming and Parameters 3-105FileGroupNameNo. DescriptionValues955 Status2 at FaultStatus 2 at FaultCaptures and displays P936 [Drive Status 2] bit pattern at the time of the last fault.Read-WriteData TypeOptionsReservedReservedReservedDecel RateAccel RatePID FB LossAutotuningPrchrgClosedReservedReservedFdbkLoss SwOFlux BrakeReservedHS Fan OnAuRstrCntDwnAutoRstr ActDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition True956 Fault FrequencyFault FrequencyCaptures and displays the output speed of the drive at the time of the last fault.957 Fault AmpsFault AmpsCaptures and displays motor amps at the time of the last fault.Default: 0.00Min/Max: –650.00 / 650.00Default: 0.00Min/Max: 0.00 / P21 [Rated Amps] x 2958 Fault Bus VoltsFault Bus VoltsCaptures and displays the DC bus voltage of the drive at the time of the last fault.Default:Min/Max:0.000.00 / P20 [Rated Volts] x 2959 Alarm Status AAlarm Status AIndicates the occurrence of conditions that have been configured as alarms. These events are from 937 [Condition Sts 1].RORORORealRealRealDIAGNOSTICSFault/Alarm InfoOptionsReservedGnd WarningReservedPosFdbkLossAuxFdbkLossAltFdbkLossPriFdbkLossShear Pin 2Shear Pin 1Dec InhibitOutPhaseLossInPhaseLossLoad LossMotor OLUnderVoltagePower LossDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0960 Alarm Status BAlarm Status BIndicates the occurrence of conditions that have been configured as alarms.0 = False1 = TrueOptionsReservedReservedPumpOff Alrm (1)OW Level TO (1)OW Level (1)Gnd WarningNot Home SetHoming ActvProfile Actv (2)PWMFrq ReducCurLmt ReducDrive OLStartOnPwrUpWakingHeatsink OTIGBT OTDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0(1) 753 drives only.(2) 755 drives only.0 = False1 = True961 Type 2 AlarmsType 2 AlarmsIndicates the occurrence of conditions that have been configured as alarms.OptionsReservedBipolarCflct (1)IXOVoltRangeFluxAmpsRangIRVltg RangeDigIn Cnfg CDigIn Cnfg BAltOpenLoopPriOpenLoopVHz IncmpbleVHzBossLmtVHzNegSlopeFrq CflctTrqProvCflct (2)BrakeSlipped (2)Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0(1) 753 drives only.(2) 755 drives only.Sleep Cfg0 = False1 = True<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!