3-144 Programming and ParametersFileGroupNo.NameDescriptionValuesRead-WriteData Type70 Anlg Out TypeAnalog Output TypeSelect the analog output mode for each analog output.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedAnalog 1Analog 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Voltage Mode1 = Current Mode71 Anlg Out AbsAnalog Output AbsoluteSelects whether the signed value or absolute value of a parameter is used before being scaled to drive the analog output.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedAnalog 1Analog 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 1Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition True75 Anlg Out0 SelAnalog Output 0 SelectSelects the source for the analog output.Default: 3Min/Max: 0 / 159999RW 32-bitIntegerHOST GROUPSAnalog Outputs76 Anlg Out0 StptAnalog Output 0 SetpointA possible source for an analog output. Can be used to control an analog outputfrom a communication device using a DataLink. Not affected by analog outputscaling.77 Anlg Out0 DataAnalog Output 0 DataDisplays the value of the source selected by P75 [Anlg Out0 Sel].Units: V<strong>AC</strong>Default: 0Min/Max: –10/20Default: 0Min/Max: –/+100000RW RealROReal78 Anlg Out0 DataHiAnalog Output 0 Data HighSets the high value for the data range of analog out scale.Default: 1Min/Max: –/+214748000RW Real79 Anlg Out0 DataLoAnalog Output 0 Data LowSets the low value for the data range of analog out scale.Default: 1Min/Max: –/+214748000RW Real80 Anlg Out0 HiAnalog Output 0 HighSets the high value for the analog output value when the data value is at itsmaximum.Units:Default:Min/Max:VoltsmA10.000 Volts20.000 mA–/+10.000 Volts0.000 / 20.000 mARW Real81 Anlg Out0 LoAnalog Output 0 LowSets the low value for the analog output value when the data value is at itsminimum.Units:Default:Min/Max:VoltsmA0.000 Volts0.000 mA–/+10.000 Volts0.000 / 20.000 mARW Real82 Anlg Out0 ValAnalog Output 0 ValueDisplays the analog output value.Units:Default:Min/Max:VoltsmA10.000 Volts20.000 mA–/+10.000 Volts0.000 / 20.000 mAROReal<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!