12.07.2015 Views

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Programming and Parameters 3-61FileGroupNo.NameDescriptionValuesRead-WriteData Type503 MtrBrngElpsdLifeMotor Bearing Elapsed LifeAccumulated hours of motor bearing run time. Hours are accumulated any timedrive is running greater than zero speed.Units: HrsDefault: 0.00Min/Max: 0.00 / 21,474,836.47 (31 bits)RO32-bitInteger504 MtrBrngRemainLifMotor Bearing Remaining LifeRemaining number of hours until estimated end of life for motor bearings, and isthe difference between P502 [MtrBrngTotalLife] and P503 [MtrBrngElpsdLife].Units: HrsDefault: 0.00Min/Max: –21,474,836.48 / 21,474,836.47RO32-bitInteger505 MtrBrngEventLvlMotor Bearing Event LevelPercent of total expected motor bearing life for which an early warning alarm orfault can be programmed.Units: %Default: 80.000Min/Max: 0 / 100.000RW Real506 MtrBrngEventActnMotor Bearing Event ActionConfigures the response to a motor bearing event, which occurs when P505[MtrBrngEventLvl] is met or exceeded.Default:Options:0 = “Ignore”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”RW 32-bitInteger507 MtrBrng ResetLogMotor Bearing Reset LogTotal number of resets performed on the P503 [MtrBrngElpsdLife] parameter.Default: 0Min/Max: 0 / 255 (unsigned 8 bits)RO32-bitIntegerPROTECTIONPredictive Main508 MtrLubeElpsdHrsMotor Lubricant Elapsed HoursAccumulated hours since the most recent lubrication of the motor bearings. Canbe reset without restriction.509 MtrLubeEventLvlMotor Lubricant Event LevelNumber of hours between scheduled lubrications of the motor bearings. Used foran early warning alarm or fault according to P510 [MtrLubeEventActn]. Event isdisabled when set to 0.Units: HrsDefault: 0.00Min/Max: 0.00 / 21,474,836.47Units: HrsDefault: 0.000Min/Max: 0.000 / 220000000.000RO32-bitIntegerRW Real510 MtrLubeEventActnMotor Lubricant Event ActionConfigures the response to a motor bearing lubrication event, which occurs whenP509 [MtrLubeEventLvl] is met or exceeded.Default:Options:0 = “Ignore”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”RW 32-bitInteger511 MchBrngTotalLifeMachine Bearing Total LifeTotal number of hours expected over the life of the machine bearings.Units: HrsDefault: Current ValueMin/Max: 0 / 21,474,836.47RW 32-bitInteger512 MchBrngElpsdLifeMachine Bearing Elapsed LifeAccumulated hours of machine bearing run time.Units: HoursDefault: 0.00Min/Max: 0 / 21,474,836.47RO32-bitInteger513 MchBrngRemainLifMachine Bearing Remaining LifeRemaining number of hours until estimated end of life for machine bearings, andis the difference between Machine Bearing Total Life and Machine BearingElapsed Life.Units: HrsDefault: 0.00Min/Max: –21,474,836.48 / 21,474,836.47RO32-bitInteger514 MchBrngEventLvlMachine Bearing Event LevelPercent of total expected machine bearing life for which an early warning alarm orfault can be programmed.Units: %Default: 80.000Min/Max: 0.000 / 100.000RW Real<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!