3-142 Programming and ParametersFileGroupNo.NameDescriptionValuesRead-WriteData Type47 Anlg In Loss StsAnalog Input Loss StatusStatus of the analog input loss.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedLoss 1Loss 0LossDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Loss not Present1 = Loss PresentHOST GROUPSAnalog InputsBit 0 “Loss” – Indicates loss of one or both inputs.50 Anlg In0 ValueAnalog Input 0 ValueValue of the Analog input after filter, square root, and loss action.51 Anlg In0 HiAnalog Input 0 HighSets the highest input value to the analog input scaling block.52 Anlg In0 LoAnalog Input 0 LowSets the lowest input value to the analog input scaling block.53 Anlg In0 LssActnAnalog Input 0 Loss ActionSelects drive action when an analog signal loss is detected. Signal loss is definedas an analog signal less than 1V or 2mA. The signal loss event ends and normaloperation resumes when the input signal level is greater than or equal to 1.5V or3mA.“Ignore” (0) – No action is taken“Alarm” (1) – Alarm occurs“Flt Minor” (2) – Minor Fault occurs if enabled, otherwise Fault Coast Stop“FltCoastStop” (3) – Fault Coast Stop occurs“Flt RampStop” (4) – Fault Ramp Stop occurs“Flt CL Stop” (5) – Fault Current Limit Stop occurs“Hold Input” (6) – Holds input at last value“Set Input Lo” (7) – Sets input to P52 [Anlg In0 Lo]“Set Input Hi” (8) – Sets input to P51 [Anlg In0 Hi]Units:Default:Min/Max:Units:Default:Min/Max:Units:Default:Min/Max:Default:Options:VoltsmA0.000 Volts0.000 mA–/+10.000 Volts0.000 / 20.000 mAVoltsmA0.000 Volts0.000 mA–/+10.000 Volts0.000 / 20.000 mAVoltsmA0.000 Volts0.000 mA–/+10.000 Volts0.000 / 20.000 mA0 = “Ignore”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”6 = “Hold Input”7 = “Set Input Lo”8 = “Set Input Hi”RORealRW RealRW RealRW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!