Using DeviceLogix G-3Parameters The following are the DeviceLogix parameters (located in Port 14).HOST GROUPSFileDigital Inputs Analog InputsAnalog Outputs GroupNo.1Thru14151617Thru30313233Thru48NameDescriptionDLX Out 01DLX Out 14Fourteen floating point outputs that can be controlled by the DeviceLogixprogram. These are typically mapped to a parameter to write its value. It can alsobe mapped to the Reference Command.DLX Out 15DLX Out 16Two unsigned 32-bit integer outputs that can be controlled by the DeviceLogixprogram. These are typically mapped to a parameter to write its value.DLX In 01DLX In 14Fourteen floating point inputs that can be read by the DeviceLogix program.These are typically mapped to a parameter to read its value. It can also bemapped to Common Feedback.DLX In 15DLX In 16Two unsigned 32-bit integer inputs that can be read by the DeviceLogix program.These are typically mapped to a parameter to read its value. It can also bemapped to Real Time Clock values.ValuesDefault: 0Min/Max: 0 / 159999Default: 0Min/Max: 0 / 159999Default: 0Min/Max: 0 / 159999Default: 0Min/Max: 0 / 159999DLX DIP 01DLX DIP 16Sixteen digital inputs that can be read by the DeviceLogix program. These aretypically mapped to an input point in an I/O option module or to Logic Status bits.Default:Min/Max:0.000 / 159999.1549 DLX DigIn StsProvides the individual on/off status of the 16 DLX DIP's.OptionsDLX DIPVal16DLX DIPVal15DLX DIPVal14DLX DIPVal13DLX DIPVal12DLX DIPVal11DLX DIPVal10DLX DIPVal9DLX DIPVal8DLX DIPVal7DLX DIPVal6DLX DIPVal5DLX DIPVal4DLX DIPVal3DLX DIPVal2DLX DIPVal1Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition Off1 = Condition OnRead-WriteData TypeRW RealRW 32-bitIntegerRW RealRW 32-bitIntegerRW 32-bitInteger50 DLX DigOut StsProvides the individual on/off status of the DLX Logic Command word bits.Status & CntlOptionsDLX CmdSts16DLX CmdSts15DLX CmdSts14DLX CmdSts13DLX CmdSts12DLX CmdSts11DLX CmdSts10DLX CmdSts9DLX CmdSts8DLX CmdSts7DLX CmdSts6DLX CmdSts5DLX CmdSts4DLX CmdSts3DLX CmdSts2DLX CmdSts1Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition Off1 = Condition On51 DLX DigOut Sts2Provides the individual on/off status of the 16 DLX DOPs.OptionsDLX DOPSts16DLX DOPSts15DLX DOPSts14DLX DOPSts13DLX DOPSts12DLX DOPSts11DLX DOPSts10DLX DOPSts9DLX DOPSts8DLX DOPSts7DLX DOPSts6DLX DOPSts5DLX DOPSts4DLX DOPSts3DLX DOPSts2DLX DOPSts1Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition Off1 = Condition On<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!