3-58 Programming and ParametersFileGroupNo.NameDescriptionValuesRead-WriteData Type456 PwrLoss RT BusKpPower Loss Ride Through Bus KpProportional gain that adjusts the response of the bus regulator when power lossride through is enabled and detected. This parameter is not functional when anyof the FV motor control modes are selected.Units: A/VDefault: 585.0Min/Max: 0.0 / 1000000.0RW Real457 PwrLoss RT BusKdPower Loss Ride Through Bus KdDerivative gain that adjusts the response of the bus regulator when power lossride through is enabled and detected. This parameter is not functional when anyof the FV motor control modes are selected.Units: SecsDefault: 50.0Min/Max: 0.0 / 1000000.0RW Real458 PwrLoss RT <strong>AC</strong>RKpPower Loss Ride Through Active Current Regulator KpUnits:Default:Hz/A524.0Proportional gain that adjusts the response of the active current regulator portion Min/Max: 0.0 / 1000000.0of the bus regulator when power loss ride through is enabled and detected. Thisparameter is not functional when any of the FV motor control modes are selected.459 PwrLoss RT <strong>AC</strong>RKiUnits: Hz/APower Loss Ride Through Active Current Regulator KiDefault: 2045.0Integral gain that adjusts the response of the active current regulator portion of Min/Max: 0.0 / 50000.0the bus regulator when power loss ride through is enabled and detected. Thisparameter is not functional when any of the FV motor control modes are selected.RW RealRW RealPROTECTIONPower Loss460 UnderVltg ActionUnder Voltage ActionConfigures the drive’s response to an under voltage event.Default:Options:3 = “FltCoastStop”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”RW 32-bitInteger461 UnderVltg LevelUnder Voltage Level<strong>AC</strong> line voltage level below which an undervoltage event occurs.462 InPhase LossActnIn Phase Loss ActionSelects action to take if an Input Phase loss is detected.Units: V<strong>AC</strong>Default: P20 [Rated Volts] x 0.625Min/Max: 0.00 / P20 [Rated Volts] x 1.41RW RealDefault:Options:3 = “FltCoastStop”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”RW 32-bitInteger463 InPhase Loss LvlDefault: 325In Phase Loss LevelMin/Max: 10 / 32767Sets the threshold level which is used to determine an Input phase loss condition.RW 32-bitInteger464 DC Bus Mem ResetDirect Current Bus Memory ResetForces a manual update to P12 [DC Bus Memory], which is automaticallyinitialized upon power-up and continually updated during normal operation. Amanual reset is rarely required, but may occur when input voltage is abnormallyhigh or low for an extended period of time followed by a fast return to a nominalvalue. A transition from 0 to 1 will cause an update, only if the drive is notregenerating and not firing the dynamic brake. The update will be ignored of notcompleted with 30 seconds of the command.Default:Options:0 = “Disabled”0 = “Disabled”1 = “Enabled”RW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!