3-40 Programming and ParametersFileGroupFEEDB<strong>AC</strong>K & I/OAnalog OutputsNameNo. Description276 753 Anlg Out0 StptAnalog Output 0 SetpointA possible source for an analog output. Can be used to control an analog outputfrom a communication device using a DataLink. Not affected by analog outputscaling.277 753 Anlg Out0 DataAnalog Output 0 DataDisplays the value of the source selected by P275 [Anlg Out0 Sel].278 753 Anlg Out0 DataHiAnalog Output 0 Data HighSets the high value for the data range of analog out scale.279 753 Anlg Out0 DataLoAnalog Output 0 Data LowSets the low value for the data range of analog out scale.280 753 Anlg Out0 HiAnalog Output 0 HighSets the high value for the analog output value when the data value is at itsmaximum.281 753 Anlg Out0 LoAnalog Output 0 LowSets the low value for the analog output value when the data value is at itsminimum.282 753 Anlg Out0 ValAnalog Output 0 ValueDisplays the analog output value.ValuesUnits: V<strong>AC</strong>Default: 0Min/Max: –10/20Default: 0Min/Max: –/+100000Default: 1Min/Max: –/+214748000Default: 1Min/Max: –/+214748000Units:Default:Min/Max:Units:Default:Min/Max:Units:Default:Min/Max:VoltsmA10.000 Volts20.000 mA–/+10.000 Volts0.000 / 20.000 mAVoltsmA0.000 Volts0.000 mA–/+10.000 Volts0.000 / 20.000 mAVoltsmA10.000 Volts20.000 mA–/+10.000 Volts0.000 / 20.000 mARead-WriteData TypeRW RealRO RealRW RealRW RealRW RealRW RealRO RealFileGroupNameNo. Description285 753 RO PredMaint StsRelay Output Predictive Maintenance StatusStatus of relay 0 predictive maintenance.ValuesRead-WriteData TypeFEEDB<strong>AC</strong>K & I/OR0 Predict MainOptionsMasterReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedRelay Out 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0286 753 RO0 Load TypeRelay Output 0 Load TypeSets the type of load that will be applied to the relay. Must be properly set for thePredictive Maintenance function to predict the relay life.Default:Options:1 = “DC Inductive”0 = “DC Resistive”1 = “DC Inductive”2 = “<strong>AC</strong> Resistive”3 = “<strong>AC</strong> Inductive”287 753 RO0 Load AmpsUnits: AmpsRelay Output 0 Load AmpsDefault: 2.000Load current that will be applied to the relay contacts. Must be properly set for the Min/Max: 0.000 / 2.000Predictive Maintenance function to approximate the relay life.288 753 RO0 TotalLifeRelay Output 0 Total LifeTotal life cycles of the relay based on programmed load type and amps.0 = Condition False1 = Condition TrueUnits: CyclDefault: 0Min/Max: 0 / 2147483647RW 32-bitIntegerRW RealRO32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!