12.07.2015 Views

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A-2 Supplemental Drive InformationCategory SpecificationEnvironment Altitude:Maximum Surrounding AirTemperature without De-ratingIP20, NEMA/UL Open Type:IP00, NEMA/UL Open Type:IP20, NEMA/UL Type 1 (w/Hood):IP20, NEMA/UL Type 1 (w/Label):Flange Mount –Front:IP20, NEMA/UL Open Type:IP00, NEMA/UL Open Type:Back/Heat Sink:IP66, NEMA/UL Type 4XStand-alone/Wall Mount –IP54, NEMA/UL Type 12Storage Temperature (all const.):Atmosphere:Relative Humidity:Shock - OperatingShock - Packaged for ShipmentVibration - OperatingVibration - Packaged for ShipmentSinusoidal Loose Load:1000 m (3300 ft) max. without derating0…50 °C (32…122 °F)0…50 °C (32…122 °F)0…40 °C (32…104 °F)0…40 °C (32…104 °F)0…50 °C (32…122 °F)0…50 °C (32…122 °F)0…40 °C (32…104 °F)Frames 2…5, All RatingsFrames 6…7, All RatingsFrames 2…5, All RatingsFrames 6…7, All RatingsFrames 2…5, All RatingsFrames 6…7, All RatingsAll Frames, All Ratings0…40 °C (32…104 °F) All Frames, All Ratings–40…70 °C (–40…158 °F)Important: Drive must not be installed in an area where theambient atmosphere contains volatile or corrosive gas,vapors or dust. If the drive is not going to be installed for aperiod of time, it must be stored in an area where it will not beexposed to a corrosive atmosphere.5…95% non-condensingFrame 2…6: 15 g peak for 11 ms duration (±1.0 ms)Frame 7: 10 g peak for 11 ms duration (±1.0 ms)Frame 2: 381 mm (15 in.) drop heightFrame 3…4: 330 mm (13 in.) drop heightFrame 5: 305 mm (12 in.) drop heightFrame 6…7: Meets International Safe Transit Association(ISTA) test procedure 2BFrame 2: 1.000 mm (0.040 in.) displacement, 2 g peakFrame 3…5: 1.000 mm (0.040 in.) displacement, 1.5 g peakFrame 6…7: 1.000 mm (0.040 in.) displacement, 1 g peakFrame 2…5: 20.0 mm (0.8 in.) peak to peak, 2…5.186 Hz;1.1 g peak from 5.186…20 HzFrame 6…7: Meets ISTA 2B packaging standardsRandom Secured:Frame 2…5: Frequency (Hz) PSD (g 2 /Hz)1 0.000054 0.0116 0.0140 0.00180 0.001200 0.00001Frame 6…7 Meets International Safe Transit Association(ISTA) test procedure 2BSound: Frame Fan Speed Sound Note: Sound pressureLevel level is measured at 2meters.Surrounding EnvironmentPollution DegreePollution Degree 1 & 2:Pollution Degree 3 & 4:(See page A-7 for descriptions ofeach pollution degree rating.)2 50 CFM 63 dB3 80 CFM 64 dB4 160 CFM 72 dB5 260 CFM 77 dB6 252 CFM 73 dB7 252 CFM 74 dBAll enclosures acceptable.Enclosure that meets or exceeds IP54, NEMA/UL Type 12required.<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!