Programming and Parameters 3-89FileGroupPOSITION CONTROLPoint to PointNameNo. Description785 PTP Fwd Vel LmtPoint-To-Point Forward Velocity LimitProvides the maximum forward speed reference limit.786 PTP Rev Vel LmtPoint-To-Point Reverse Velocity LimitProvides the maximum reverse speed reference limit.787 PTP S CurvePoint-To-Point S CurveProvides the amount of time that is applied to the S Curve.788 PTP Vel OverridePoint-To-Point Velocity OverrideProvides multiplier to both forward P785 [PTP Fwd Vel Lmt] and reverse P786[PTP Rev Vel Lmt] speed limits. This parameter applies to the speed limits whenthe override bit P770 [PTP Control] Bit 0 “Vel Override” is on.789 PTP EGR MultPoint-To-Point Electronic Gear Ratio MultiplyEGR multiplier (numerator) for position index output. The output applies to thepoint-to-point command P784 [PTP Command].790 PTP EGR DivPoint-To-Point Electronic Gear Ratio DivideEGR divider (denominator) for position index output. The output applies to thepoint-to-point command P784 [PTP Command].ValuesUnits:Default:Min/Max:Units:Default:Min/Max:HzRPMP27 [Motor NP Hertz] x 0.5P28 [Motor NP RPM] x 0.50.00/P27 [Motor NP Hertz]0.00/P28 [Motor NP RPM]HzRPMP27 [Motor NP Hertz] x 0.5P28 [Motor NP RPM] x 0.50.00/P27 [Motor NP Hertz]0.00/P28 [Motor NP RPM]Units: SecsDefault: 0.500Min/Max: 0.000 / 4.000Default: 1.00Min/Max: 0.20 / 1.50Default: 1Min/Max: –/+2000000Default: 1Min/Max: 1 / 2000000Read-WriteData TypeRW RealRW RealRW RealRW RealRW 32-bitIntegerRW 32-bitIntegerFileGroupNameNo. Description795 755 PLL ControlPhase Locked Loop ControlSets bits to configure the phase locked loop control.ValuesRead-WriteData TypePOSITION CONTROLPhase Lock LoopOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedProf EnablePTP EnablePCAM EnableAccel CompExt Vel FFVelocity FFPLL EnableDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0Bit 0 “PLL Enable” – enables the phase locked loop control.Bit 1 “Velocity FF” – enables the velocity feed forward path.Bit 2 “Ext Vel FF” – enables the external velocity feed forward through the PLL external speed reference selected by the PLL external speed selectionP796 [PLL Ext Spd Sel].Bit 3 “Accel Comp” – enables providing an element of acceleration compensation to the feed forward branch. This is not recommended for use withexternal inputs because of increased noise.Bit 4 “PCAM Enable” – enables PCAM function with the PLL function.Bit 5 “PTP Enable” – enables point-to-point function with the PLL function.Bit 6 “Prof Enable” – enables profiler function with the PLL function.Only bits 4, 5, and 6 allow associating with the PLL function.796 755 PLL Ext Spd SelPhase Locked Loop External Speed SelectSelects an external speed reference source.0 = False1 = TrueDefault:Options:7971 / 159999RW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!