Programming and Parameters 3-3How Drive Parameters areOrganizedDriveExecutive programming software displays parameters in “Linear List”or “File Group Parameter” format. Viewing the parameters in “File GroupParameter” format simplifies programming by grouping parameters that areused for similar functions. There are eleven files. Each file is divided intomultiple groups of parameters.Parameter descriptions begin on page 3-19.Basic Parameter ViewParameter 301 [Access Level] set to option 0 “Basic.”File Group ParametersMonitor Metering Output Frequency 1Commanded SpdRef 2Mtr Vel Fdbk 3Commanded Trq 4MonitorTorque Cur Fdbk 5Flux Cur Fdbk 6Output Current 7Output Voltage 8Output Power 9DC Bus Volts 11Drive Data Rated Volts 20 Rated Amps 21 Rated kW 22Motor Control Motor Data Motor NP Volts 25Motor NP Amps 26Motor ControlMotor NP Hertz 27Motor NP RPM 28Mtr Ctrl Options Motor Ctrl Mode 35 Maximum Voltage 36Maximum Freq 37Volts per Hertz VHz Curve 65Autotune Autotune 70 Autotune Torque 71Feedback & I/O Digin Functions Digital In Cfg 150DI Enable 155DI Clear Fault 156DI Aux Fault 157DI Stop 158DI Cur Lmt Stop 159DI Coast Stop 160DI Start 161DI Fwd Reverse 162DI Run 163DI Run Forward 164DI Run Reverse 165Feedback and IODI Jog 1 166DI Jog 1 Forward 167DI Jog 1 Reverse 168DI Jog 2 169DI Jog 2 Forward 170DI Jog 2 Reverse 171DI <strong>Manual</strong> Ctrl 172DI Speed Sel 0 173DI Speed Sel 1 174DI Speed Sel 2 175Mtr NP Pwr Units 29Motor NP Power 30PWM Frequency 38DI Accel 2 179DI Decel 2 180Digital Inputs Digital In Sts 220 Dig In Filt Mask 753 222 Dig In Filt 753 223Digital Outputs 753 Dig Out Sts 225Dig Out Invert 226Dig Out Setpoint 227RO0 Sel 230RO0 Level Sel 231RO0 Level 232RO0 Level CmpSts 233RO0 On Time 234RO0 Off Time 235Motor PTC 753 PTC Cfg 250 PTC Status 251Analog Inputs 753 Anlg In Type 255Anlg In Sqrt 256Anlg In Loss Sts 257Analog Outputs 753 Anlg Out Type 270Anlg Out Abs 271Anlg In0 Value 260Anlg In0 Hi 261Anlg In0 Lo 262Anlg Out0 Sel 275Anlg Out0 Stpt 276TO0 Sel 240TO0 Level Sel 241TO0 Level 242TO0 Level CmpSts 243TO0 On Time 244TO0 Off Time 245Anlg In0 LssActn 263Anlg In0 Raw Val 264Anlg Out0 Data 277Anlg Out0 DataHi 278Anlg Out0 DataLo 279Motor Poles 31Anlg In0 Filt Gn 265Anlg In0 Filt BW 266Anlg Out0 Hi 280Anlg Out0 Lo 281Anlg Out0 Val 282<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!