3-104 Programming and ParametersFileGroupRead-WriteData TypeNo.NameDescriptionValues950 Minor Flt CfgMinor Fault ConfigurationEnables / Disables operation of the “Minor Fault” function, which allows the drive to continue running while some types of faults are present. Inaddition to setting this parameter, the “Flt Minor” action must be selected for the condition that is desired to result in a minor fault (see P410 for anexample).OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedEnableDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition True951 Last Fault CodeLast Fault CodeThe fault code of the most recent fault. This parameter is for convenience. Acomprehensive history of fault information is available through the fault que (viaHIM screens and / or software tools such as Drive Explorer).Default: 0Min/Max: 0 / 424648720952 Fault Status AFault Status AIndicates the occurrence of conditions that have been configured as faults. These conditions are from 937 [Condition Sts 1].RO32-bitIntegerDIAGNOSTICSFault/Alarm InfoOptionsReservedReservedExtPrchrgErrPosFdbkLossAuxFdbkLossAltFdbkLossPriFdbkLossShear Pin 2Shear Pin 1Dec InhibitOutPhaseLossInPhaseLossLoad LossMotor OLUnderVoltagePower LossDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0953 Fault Status BFault Status BIndicates the occurrence of conditions that have been configured as faults.0 = False1 = TrueOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedOver Travel (1)OW Alarm TO (1)Ground FaultTPEnclsCnfg (2)TrqPrvSpdBnd (2)Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0(1) 753 drives only.0 = False(2) 755 drives only.1 = True954 Status1 at FaultStatus 1 at FaultCaptures and displays P935 [Drive Status 1] bit pattern at the time of the last fault.OptionsHW OverCurSW OverCurAuRstExhaustIXOVoltRangeFluxAmpsRangIRVoltsRangeSafetyBrdFltPrchrg OpenOverspd LmtExcess LoadSinkUnderTmpTransistorOTHeatsink OTDrive OLOverVoltageAux InputFltRegenMotor OLEnable OnBus Frq RegCur LimitAt LimitAt HomeAtZero SpeedTorque ModePositionModeSpeed ModeDB ActiveDC BrakingStoppingJoggingRunningReservedSpdRef Bit 4SpdRef Bit 3SpdRef Bit 2SpdRef Bit 1SpdRef Bit 0<strong>Manual</strong>At SpeedFaultedAlarmDeceleratingAcceleratingActual DirCommand DirActiveReadyDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!