1-42 Installation/WiringInput/Output Connection Example Required Parameter ChangesHW Input PTCPTC Nominal = 1.8 k Ohm• ConfigurationPort X (I/O Module): P40 [PTC Cfg] = 0 “Ignore,” 1 “Alarm,” 2 “Flt Minor,”PTC Trip = 3.1k Ohm1.8kPtc– 3 “Flt CoastStop,” 4 “Flt RampStop,” or 5 “Flt CL Stop”PTCPTC Reset = 2.2 kOhmPtc+• View ResultsPort X (I/O Module): P41 [PTC Sts]Port X (I/O Module): P42 [PTC Raw Value]!Analog Voltage Output±10V, 0…20 mA Bipolar+10V Unipolar2-Wire ControlNon-Reversing24V DC internal supply2-Wire ControlReversingExternal supply3-Wire ControlInternal supplyATTENTION: To avoid an electric shock hazard, theconnection of the motor temperature sensor requires double orreinforced insulation between motor live parts and the PTC.+Stop-Run+24V CommonRun FwdRun RevStopStart–Ao0–Ao0+24VC+24VDi CDi 0Di CDi 0Di 124VC+24VDi CDi 0Di 1• ConfigurationPort X (I/O Module): P70 [Anlg Out Type], bit 0 = 0• Set SelectionPort X (I/O Module): P75 [Anlg Out0 Sel] = Port 0: P3 [Mtr Vel Fdbk]• Adjust ScalingPort X (I/O Module): P78 [Anlg Out0 DataHi] = 60 HzPort X (I/O Module): P79 [Anlg Out0 DataLo] = 0 HzPort X (I/O Module): P80 [Anlg Out0 Hi] =10V/20 mAPort X (I/O Module): P81 [Anlg Out0 Lo] = 0V/0 mA• View ResultsPort X (I/O Module): P77 [Anlg Out0 Data]Port X (I/O Module): P82 [Anlg Out0 Val]• Set Direction ModePort 0: P308 [Direction Mode] = 2 “Rev Disable”• ConfigurationPort 0: P150 [Digital In Cfg] = 1 “Run Level”• Set SelectionPort 0: P163 [DI Run] = Port X (I/O Module): P1 [Dig In Sts], bit 0 = Input 0• View ResultsPort X (I/O Module): P1 [Dig In Sts]Port 0: P935 [Drive Status 1]• Set Direction ModePort 0: P308 [Direction Mode] = 0 “Unipolar”• ConfigurationPort 0: P150 [Digital In Cfg] = 1 “Run Level”• Set SelectionPort 0: P164 [DI Run Forward] = Port X (I/O Module): P1 [Dig In Sts], bit 0 =Input 0Port 0: P165 [DI Run Reverse] = Port X (I/O Module): P1 [Dig In Sts], bit 1 =Input 1• View ResultsPort X (I/O Module): P1 [Dig In Sts]Port 0: P935 [Drive Status 1]• Set SelectionPort 0: P158 [DI Stop] = Port X (I/O Module): P1 [Dig In Sts], bit 0 = Input 0Port 0: P161 [DI Start] = Port X (I/O Module): P1 [Dig In Sts], bit 1 = Input 1• View ResultsPort X (I/O Module): P1 [Dig In Sts]Port 0: P935 [Drive Status 1]3-Wire ControlExternal supply+24V CommonStopStartDi CDi 0Di 1• Set SelectionPort 0: P158 [DI Stop] = Port X (I/O Module): P1 [Dig In Sts], bit 0 = Input 0Port 0: P161 [DI Start] = Port X (I/O Module): P1 [Dig In Sts], bit 1 = Input 1• View ResultsPort X (I/O Module): P1 [Dig In Sts]Port 0: P935 [Drive Status 1]<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!