3-180 Programming and ParametersFileGroupNameNo. Description52 755 Web EnableWeb EnabledEnables/disables the adapter web page features.53 755 Web FeaturesWeb FeaturesEnables/disables the Web-configurable e-mail notification feature.ValuesDefault:Options:1 = “Enabled”0 = “Disabled”1 = “Enabled”Read-WriteData TypeRW 32-bitIntegerOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedE-mail CfgDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Disabled1 = Enabled54 755 Comm Flt ActionDefault:Communication Fault ActionOptions:Sets the action that the adapter and drive will take if the adapter detectsthat I/O communications have been disrupted. This setting is effectiveonly if I/O that controls the drive is transmitted through the adapter.0 = “Fault”0 = “Fault”1 = “Stop”2 = “Zero Data”3 = “Hold Last”4 = “Send Flt Cfg”RW 32-bitIntegerHOST GROUPS!55 755 Idle Flt ActionATTENTION: Risk of injury or equipment damage exists. P54 [Comm Flt Action] lets you determine theaction of the adapter and connected drive if I/O communications are disrupted. By default, this parameterfaults the drive. You can set this parameter so that the drive continues to run. Precautions should be taken toensure that the setting of this parameter does not create a risk of injury or equipment damage. Whencommissioning the drive, verify that your system responds correctly to various situations (for example, adisconnected cable).Idle Fault ActionSets the action that the adapter and drive will take if the adapter detects that thecontroller is in program mode or faulted. This setting is effective only if I/O thatcontrols the drive is transmitted through the adapter.Default:Options:0 = “Fault”0 = “Fault”1 = “Stop”2 = “Zero Data”3 = “Hold Last”4 = “Send Flt Cfg”RW 32-bitInteger!ATTENTION: Risk of injury or equipment damage exists. P55 [Idle Flt Action] lets you determine theaction of the adapter and connected drive when the controller is idle. By default, this parameter faults thedrive. You can set this parameter so that the drive continues to run. Precautions should be taken to ensure thatthe setting of this parameter does not create a risk of injury or equipment damage. When commissioning thedrive, verify that your system responds correctly to various situations (for example, a controller in idle state).56 755 Peer Flt ActionPeer Fault ActionSets the action that the adapter and drive will take if the adapter detects that PeerI/O communications have been disrupted. This setting is effective only if I/O istransmitted through the adapter.Default:Options:0 = “Fault”0 = “Fault”1 = “Stop”2 = “Zero Data”3 = “Hold Last”4 = “Send Flt Cfg”RW 32-bitInteger!ATTENTION: Risk of injury or equipment damage exists. P56 [Peer Flt Action] lets you determine theaction of the adapter and connected drive if the adapter is unable to communicate with the designated peer.By default, this parameter faults the drive. You can set this parameter so that the drive continues to run.Precautions should be taken to ensure that the setting of this parameter does not create a risk of injury orequipment damage. When commissioning the drive, verify that your system responds correctly to varioussituations (for example, a disconnected cable).<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!