Programming and Parameters 3-117FileGroupAPPLICATIONSPump JackNameNo. Description1177 753 Min Rod SpeedMinimum Rod SpeedSets the minimum speed for the polished rod in a PCP oil well application.1178 753 Motor SheaveMotor SheaveSets the sheave diameter on the motor.1179 753 OilWell Pump CfgOil Well Pump ConfigureSelects the type of oil well application.“Disable” (0) – Disables oil well parameters.“Pump Jack” (1) – Sets parameters based on Pump Jack type oil well.“PC Oil Well” (2) – Sets parameters based on Progressive Cavity type Pumps.1180 753 PCP Pump SheavePCP Pump SheaveSpecifies the pump sheave diameter.1181 753 Gearbox LimitGearbox LimitSets the gearbox torque limit. This value is used in determining the P670 [PosTorque Limit] and P671 [Neg Torque Limit].1182 753 Gearbox RatingGearbox RatingSets the gearbox rating.1183 753 Gearbox RatioGearbox RatioSpecifies the nameplate gear ratio.1184 753 Gearbox SheaveGearbox SheaveSets the Sheave diameter on the GearboxValuesUnits: RPMDefault: 0.0Min/Max: 0.0 / 199.0Units: InchDefault: 10.0Min/Max: 0.25 / 25.00Default:Options:0 = “Disable”0 = “Disable”1 = “Pump Jack”2 = “PC Oil Well”Units: InchDefault: 20.0Min/Max: 0.25 / 200.00Units: %Default: 100.0Min/Max: 0.0 / 200.0Units: Kin#Default: 640.0Min/Max: 16.0 / 2560.0Default: 1.0Min/Max: 1.0 / 40.0Units: InchDefault: 0.25Min/Max: 0.25 / 100.00Read-WriteData TypeRW RealRW RealRW 32-bitIntegerRW RealRW RealRW RealRW RealRW RealFileGroupAPPLICATIONSPump OffNameNo. Description1187 753 Pump Off ConfigPump Off ConfigureSelects the torque data that will be used for the Pump-Off control.“Automatic” (0) – Auto select.“Position” (1) – Downstroke torque.“Cycle” (2) – Full Stroke torque.1188 753 Pump Off SetupPump Off SetupSelect Pump-Off options.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedCycle PO PosPos Min TrqPos OffsetPos FilterDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0ValuesDefault:Options:0 = Disabled1 = Enabled0 = “Automatic”0 = “Automatic”1 = “Position”2 = “Cycle”Read-WriteData TypeRW 32-bitInteger1189 753 Pump Off ActionPump Off ActionSelects the action to be taken after a Pump-Off condition has been detected.Default:Options:0 = “Change Speed”0 = “Change Speed”1 = “Always Stop”2 = “Stop After 1”3 = “Stop After 2”RW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!