Programming and Parameters 3-39FileGroupFEEDB<strong>AC</strong>K & I/OAnalog InputsNameDescriptionNo.263 753 Anlg In0 LssActnAnalog Input 0 Loss ActionSelects drive action when an analog signal loss is detected. Signal loss is definedas an analog signal less than 1V or 2mA. The signal loss event ends and normaloperation resumes when the input signal level is greater than or equal to 1.5V or3mA.“Ignore” (0) – No action is taken“Alarm” (1) – Alarm occurs“Flt Minor“ (2) – Minor Fault occurs if enabled, otherwise Fault Coast Stop“FltCoastStop“ (3) – Fault Coast Stop occurs“Flt RampStop“ (4) – Fault Ramp Stop occurs“Flt CL Stop“ (5) – Fault Current Limit Stop occurs“Hold Input” (6) – Holds input at last value“Set Input Lo” (7) – Sets input to P262 [Anlg In0 Lo]“Set Input Hi” (8) – Sets input to P261 [Anlg In0 Hi]264 753 Anlg In0 Raw ValAnalog Input 0 Raw ValueRaw Value of the analog input.265 753 Anlg In0 Filt GnAnalog Input 0 Filter GainSets the analog input filter gain.266 753 Anlg In0 Filt BWAnalog Input 0 Filter BandwidthSets the analog input filter bandwidth.ValuesDefault:Options:Units:Default:Min/Max:Default: 1.00Min/Max: –/+5.000 = “Ignore”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”6 = “Hold Input”7 = “Set Input Lo”8 = “Set Input Hi”VoltsmA0.000 Volts0.000 mA–/+10.000 Volts0.000 / 20.000 mADefault: 0.0Min/Max: 0.0 / 500.0Read-WriteRW 32-bitIntegerRORealRW RealRW RealData TypeFileGroupNameNo. Description270 753 Anlg Out TypeAnalog Output TypeSelect the analog output mode for each analog output.ValuesRead-WriteData TypeFEEDB<strong>AC</strong>K & I/OAnalog OutputsOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedAnalog Out 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Voltage Mode1 = Current Mode271 753 Anlg Out AbsAnalog Output AbsoluteSelects whether the signed value or absolute value of a parameter is used before being scaled to drive the analog output.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedAnalog Out 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Voltage Mode1 = Current Mode275 753 Anlg Out0 SelAnalog Output 0 SelectSelects the source for the analog output.Default: 3Min/Max: 0 / 159999RW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!