Programming and Parameters 3-119FileGroupAPPLICATIONSPump OffNameDescriptionNo.1204 753 Pump Off SleepCntPump Off Sleep CountDisplays the number of times a sleep condition has occurred since this parameterwas reset.1205 753 Day Stroke CountDay Stroke CountDisplays the number of strokes for the past 24 hours. This is a rolling counterupdated every hour.1206 753 DI PumpOff DisblDigital Input Pump Off DisableSelects the digital input source for the Pump Off Disable function.1207 753 Pump OffSleepLvlPump Off Sleep LevelProvides a source for P351 [SleepWake RefSel]. This provides the start/stopcontrol of the drive by the Pump-Off function.ValuesDefault: 0.00Min/Max: 0.00 / 60000.00Default: 0.00Min/Max: 0.00 / 65535.00Default: 0.00Min/Max: 0.00 / 159999.15Units: SecsDefault: 0.00Min/Max: 0.00 / 10.00Read-WriteData TypeRW RealRORealRW 32-bitIntegerRO32-bitIntegerFileGroupNameNo. Description1210 755 Profile StatusProfile StatusIndicates status of speed profile/position indexer control logic.ValuesRead-WriteData TypeAPPLICATIONSProfilingOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedHome Not SetVel OverrideRestart StepResumeStoppedCompleteIn PositionHoldingDwellPositionModeRunningEnabledReservedReservedReservedStep Bit 4Step Bit 3Step Bit 2Step Bit 1Step Bit 0Default 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = TrueBit 0 “Step Bit 0” – Bit 0 through Bit 4 indicate executing step number in the move table in binary format.Bit 1 “Step Bit 1”Bit 2 “Step Bit 2”Bit 3 “Step Bit 3”Bit 4 “Step Bit 4”Bit 8 “Enabled” – Indicates that the profile control logic is enabled. When the drive is started with the profiler selection (Option 6) in the speed/torque/position mode P313 [Actv SpTqPs Mode], this bit turns on.Bit 9 “Running” – Indicates that the profile control logic is in running state.Bit 10 “PositionMode” – Indicates that the profile control logic is using position control logic.Bit 11 “Dwell” – Indicates that the profile control logic is in dwell state.Bit 12 “Holding” – Indicates that the profile control logic is in holding statesBit 13 “In Position” – Indicates that the target position has been reached at the completion of a move. The in position bandwidth P726 [In Pos PsnBand] can be adjusted to affect when this bit is set with respect to the target position. This bit will be cleared when a new move is begunBit 14 “Complete” – Indicates that all steps in the move table have been executed and a step with a End action has been reached. The profile controllogic is complete. This bit will be cleared when the profile is first enabled.Bit 15 “Stopped” – Indicates that the profile control logic stops the drive following Bit 14 “Complete” and any additional dwell time specified for the Endstep. This bit will be cleared when a new profile is begun.Bit 16 “Resume” – Indicates that an existing step is to resume execution when the profile is enabled. A previously running step will then be allowed tocomplete. When the bit is clear, the profile will begin at its Starting Step.Bit 17 “Restart Step” – Follows the state of the restart step bit in P1213 [Profile Command] Bit 10 “Restart Step”.Bit 18 “Vel Override” – Follows the state of the velocity override bit in P1213 [Profile Command] Bit 9 “Vel Override”.Bit 19 “Home Not Set” – Indicates that the home position is not defined and the move table contains a position absolute move type. When this bit isset the profile will not be allowed to execute. This bit will be cleared when either a homing function or position redefine function is completed.<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!