Programming and Parameters 3-147FileGroupNo.NameDescriptionValuesRead-WriteData Type110 RO1 Load TypeRelay Output 1 Load TypeSets the type of load that will be applied to the relay. Must be properly set for thePredictive Maintenance function to predict the relay life.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.Default:Options:1 = “DC Inductive”0 = “DC Resistive”1 = “DC Inductive”2 = “<strong>AC</strong> Resistive”3 = “<strong>AC</strong> Inductive”RW 32-bitInteger111 RO1 Load AmpsRelay Output 1 Load AmpsLoad current that will be applied to the relay contacts. Must be properly set for thePredictive Maintenance function to approximate the relay life.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.Units: AmpsDefault: 2.000Min/Max: 0.000 / 2.000RW Real112 RO1 TotalLifeRelay Output 1 Total LifeTotal life cycles of the relay based on programmed load type and amps.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.113 RO1 ElapsedLifeRelay Output 1 Elapsed LifeNon-resettable, total accumulated cycles of the relay.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.114 RO1 RemainLifeRelay Output 1 Remaining LifeThe difference between the Total Life and the Elapsed Life.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.115 RO1 LifeEvntLvlRelay Output 1 Life Event LevelSets the percentage of relay life cycles before action is taken.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.116 RO1 LifeEvntActnRelay Output 1 Life Event ActionSets the action that will be taken when the percentage of relay life cycles hasbeen reached.Important: Only used by I/O Module models 20-<strong>750</strong>-2262C-2R and20-<strong>750</strong>-2262D-2R.“Ignore” (0) – No action is taken“Alarm” (1) – Alarm occurs“Flt Minor” (2) – Minor Fault occurs if enabled, otherwise Fault Coast Stop“FltCoastStop” (3) – Fault Coast Stop occurs“Flt RampStop” (4) – Fault Ramp Stop occurs“Flt CL Stop” (5) – Fault Current Limit Stop occursUnits: CyclDefault: 0Min/Max: 0 / 2147483647RO32-bitIntegerHOST GROUPSPredictive MainUnits: CyclDefault: 0Min/Max: 0 / 2147483647Units: CyclDefault: 0Min/Max: –/+2147483647RORO32-bitInteger32-bitIntegerUnits: %Default: 80.000Min/Max: 0.000 / 100.000RW RealDefault:Options:1 = “Alarm”0 = “Ignore”1 = “Alarm”2 = “Flt Minor”3 = “FltCoastStop”4 = “Flt RampStop”5 = “Flt CL Stop”RW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!