Programming and Parameters 3-49FileDRIVE CFGGroupStart FeaturesNameNo. Description354 Wake LevelWake LevelDefines the analog input level that will start the drive.Units:Default:Min/Max:355 Wake TimeWake TimeUnits:Default:Secs0.00Defines the amount of time at or above 354 [Wake Level] before a Start is issued. Min/Max: 0.00 / 1000.0356 FlyingStart ModeFlying Start ModeEnables/disables the function which reconnects to a spinning motor at actualRPM when a start command is issued.357 FS GainFlying Start GainP356 [FlyingStart Mode] = 1 “Enhanced”: Proportional term used in the currentregulator which controls the reconnect function.P356 [FlyingStart Mode] = 2 “Sweep”: Time required for the speed detectionsignal to remain at the programmed level (P360). Units of 50 µs.358 FS KiFlying Start Intergal GainP356 [FlyingStart Mode] = 1 “Enhanced”: Integral term used in the currentregulator which controls the reconnect function.P356 [FlyingStart Mode] = 2 “Sweep”: Integral term used in the voltage recoveryto the normal V/Hz level.359 FS Speed Reg KiFlying Start Speed Regulator Intergal GainP356 [FlyingStart Mode] = 1 “Enhanced”: Integral term used in the speedregulator which controls the reconnect function.P356 [FlyingStart Mode] = 2 “Sweep”: Time to sweep frequency in one direction.Units of 10 µs.360 FS Speed Reg KpFlying Start Speed Regulator Proportional GainP356 [FlyingStart Mode] = 1 “Enhanced”: Proportional term used in the speedregulator which controls the reconnect function.P356 [FlyingStart Mode] = 2 “Sweep”: Programmed level for the speed detectionsignal. The monitored signal needs to drop below this level to indicate motorspeed.361 FS Excitation KiFlying Start Excitation Intergal GainP356 [FlyingStart Mode] = 1 “Enhanced”: Integral term used in the currentregulator which controls the excitation function when the need is determined bythe reconnect function.P356 [FlyingStart Mode] = 2 “Sweep”: Integral term used to control initial outputvoltage.362 FS Excitation KpFlying Start Excitation Proportional GainP356 [FlyingStart Mode] = 1 “Enhanced”: Proportional term used in the currentregulator which controls the excitation function when the need is determined bythe reconnect function.P356 [FlyingStart Mode] = 2 “Sweep”: Proportional term used to control initialoutput voltage.ValuesDefault:Options:V<strong>AC</strong>, P351 = 0 (Disabled)V<strong>AC</strong> or mA, P351 = not 0 (Port X DeviceJumper Setting)6.00 V<strong>AC</strong> (P351 = 0)6.00 V<strong>AC</strong> / 12.00 mA (Port X DeviceJumper Setting)0.00 / 10.00 V<strong>AC</strong>0.00 / 20.00 mA0 = “Disabled”0 = “Disabled”1 = “Enhanced”2 = “Sweep”Default: 1200.0Min/Max: 0.0 / 10000.0Default: 60.0Min/Max: 0.0 / 1000.0Default: 100.0Min/Max: 0.0 / 10000.0Default: 75.0Min/Max: 0.0 / 100000.0Default: 60.0Min/Max: 0.0 / 32767.0Default: 1200.00Min/Max: 0.0 / 32767.0Read-WriteRW RealRW RealRW 32-bitIntegerRW RealRW RealRW RealRW RealRW RealRW RealData Type<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!