Troubleshooting 4-9EventFault Configuration AutoNo. Fault/Alarm Text Type Action Parameter Reset Description/Action(s)193 Rev Spd Lim Cfg Alarm 2 The reverse speed reference is out of range.Verify the settings of P38 [PWM Frequency] and P521 [MaxRev Speed]. Lower carrier frequencies reduce the outputfrequency range.Verify that P523 [Min Rev Speed] is less than P521 [MaxRev Speed].203 Port 13 Adapter ResettableFaultCoastThe embedded EtherNet/IP adapter has a fault. SeeEtherNet event queue.204 Port 14 Adapter Resettable CoastThe DeviceLogix adapter has a fault.Fault205 DPI TransportErr Alarm 1 A DPI Communication Error has occurred.210 HW En Jumper Out ResettableFaultCoastA Safety Option module is present and Jumper J1 ENABLEis removed. Install the jumper.211 Safety Brd Fault ResettableFaultCoastA Safety option module has indicated a fault. Verify thatJumper J1 ENABLE is installed. Reset or power cycle drive.212 Safety JumperOut ResettableFaultCoastJumper J2 SAFETY is not installed and a Safety optionmodule is not present. Install the jumper.213 Safety Jumper In ResettableFaultCoastJumper J2 SAFETY is installed and a Safety option moduleis present. Remove the jumper.214 SafetyPortCnflct Alarm 2 Allowable number of safety options exceeded.224 Port 4 Comm Loss Resettable CoastThe device at the port has stopped communicating with the225 Port 5 Comm Loss Faultmain control board.226 Port 6 Comm LossVerify that the device is present and functional.Verify network connections.227 Port 7 Comm LossVerify options installed in ports 4…8 are seated in the port228 Port 8 Comm Lossand secured with mounting screws.229 Port 9 Comm Loss230 Port10 Comm Loss231 Port11 Comm Loss232 Port12 Comm Loss233 Port13 Comm Loss234 Port14 Comm Loss244 Port 4 Cfg Alarm 2 The main control board does not have the correct option in245 Port 5 Cfgthe port.246 Port 6 CfgOption may not be compatible with product or MCB firmwareneeds to be updated to support it. Option my have to be247 Port 7 Cfgmoved or removed, accept option configuration change.248 Port 8 Cfg249 Port 9 Cfg250 Port 10 Cfg251 Port 11 Cfg252 Port 12 Cfg253 Port 13 Cfg254 Port 14 Cfg264265Port 4 ChecksumPort 5 ChecksumResettableFault266 Port 6 Checksum267 Port 7 Checksum268 Port 8 Checksum269 Port 9 Checksum270 Port10 Checksum271 Port11 Checksum272 Port12 Checksum273 Port13 Checksum274 Port14 ChecksumCoastA option module storage checksum failed.Option data has been set to default values.<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!