3-24 Programming and ParametersFileGroupNo.NameDescriptionValuesRead-WriteData Type70 AutotuneAutotuneProvides a manual or automatic method for setting P73 [IR Voltage Drop], P74[Ixo Voltage Drop] and P75 [Flux Current Ref]. Valid only when parameter P35[Motor Ctrl Mode] is set to 1 “Induction SV”, 2 “Induct Econ”, or 3 “Induction FV”.“Ready” (0) – Parameter returns to this setting following a “Static Tune” or “RotateTune”, at which time another start transition is required to operate the drive innormal mode. It also permits manually setting P73 [IR Voltage Drop], P74 [IxoVoltage Drop] and P75 [Flux Current Ref].“Calculate” (1) – Uses motor nameplate data to automatically set P73 [IR VoltageDrop], P74 [Ixo Voltage Drop], P75 [Flux Current Ref] and P621 [Slip RPM @FLA].“Static Tune” (2) – A temporary command that initiates a non-rotational motorstator resistance test for the best possible automatic setting of P73 [IR VoltageDrop] in all valid modes and a non-rotational motor leakage inductance test forthe best possible automatic setting of P74 [Ixo Voltage Drop] in a Flux Vector (FV)mode. A start command is required following initiation of this setting. Used whenmotor cannot be rotated.“Rotate Tune” (3) – A temporary command that initiates a “Static Tune” followedby a rotational test for the best possible automatic setting of P75 [Flux CurrentRef]. In Flux Vector (FV) mode, with encoder feedback, a test for the bestpossible automatic setting of P621 [Slip RPM @ FLA] is also run. A startcommand is required following initiation of this setting. Important: If using rotatetune for a Sensorless Vector (SV) mode, the motor should be uncoupled from theload or results may not be valid. With a Flux Vector (FV) mode, either a coupledor uncoupled load will produce valid results.Default:Options:1 = “Calculate”0 = “Ready”1 = “Calculate”2 = “Static Tune”3 = “Rotate Tune”4 = “Inertia Tune”RW 32-bitIntegerMOTOR CONTROLAutotune!ATTENTION: Rotation of the motor in an undesireddirection can occur during this procedure. To guard againstpossible injury and/or equipment damage, it is recommendedthat the motor be disconnected from the load beforeproceeding.“Inertia Tune” (4) – A temporary command that initiates an inertia test of themotor/load combination. The motor will ramp up and down while the drivemeasures the amount of inertia.71 Autotune TorqueAutotune TorqueThe motor torque applied to the motor during the flux current and inertia tests.73 IR Voltage DropIR Voltage DropValue of voltage drop across the resistance of the motor stator at rated motorcurrent. Used only when P35 [Motor Ctrl Mode] is set to 1 “Induction SV”, 2“Induct Econ”, or 3 “Induction FV”.Units: %Default: 50.00Min/Max: 0.00 / 200.00RW RealUnits: V<strong>AC</strong>Default: Based on Drive RatingMin/Max: 0.00 / Based on Drive RatingRW Real74 Ixo Voltage DropIxo Voltage DropValue of voltage drop across the leakage inductance of the motor at rated motorcurrent. Used only when P35 [Motor Ctrl Mode] is set to 1 “Induction SV”, 2“Induct Econ”, or 3 “Induction FV”.Units: V<strong>AC</strong>Default: P25 [Motor NP Volts] x 0.25Min/Max: 0.00 / P25 [Motor NP Volts]RW Real75 Flux Current RefFlux Current ReferenceValue of amps for full motor flux.76 Total InertiaTotal InertiaTime in seconds for a motor coupled to a load to accelerate from zero to basespeed at rated motor torque. Calculated during auto-tune.77 Inertia Test LmtInertia Test LimitMaximum number of revolutions the motor rotates during the Inertia AutoTunetest. When the value is zero, the limit is not active.Units: AmpsDefault: P26 [Motor NP Amps] x 0.35Min/Max: 0.00 / P26 [Motor NP Amps] x 0.995RW RealUnits: SecsDefault: 2.00Min/Max: 0.01 / 600.00RW RealUnits: RevsDefault: 0.0Min/Max: 0.0 / 65535.0RW Real<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!