3-114 Programming and ParametersFileGroupAPPLICATIONSFiber FunctionsNameDescriptionNo.1124 753 Traverse DecTraverse DecrementSets the time period in seconds of decreasing speed for the Fiber Traversefunction.1125 753 Max TraverseMaximum TraverseSets the amplitude of the triangle wave speed modulation for the Fiber Traversefunction. The total speed variation will be twice this value, from speed ref plusMax Traverse to speed ref minus Max Traverse.1126 753 P JumpPosition JumpSets the amplitude of the square wave speed modulation for the Fiber Traversefunction. This speed is alternately added to and subtracted from the speedreference together with the [Max Traverse] triangle speed modulation.1129 753 DI Fiber SyncEnaDigital Input Fiber Synchronize EnableSelects a digital input source for the Fiber Application Functions's synchronousspeed change routine. Used in combination with the [Fiber Control] Sync Enablebit.1130 753 DI Fiber TravDisDigital Input Fiber Traverse DisableSelects a digital input source for the Fiber Application Traverse Routine. This isan inverted input, so the Traverse Routine is disabled when the input is active(set). Used in combination with the [Fiber Control] Traverse Ena bit.ValuesUnits: SecsDefault: 0.00Min/Max: 0.00 / 30.00Units: HzDefault: 0.00Min/Max: 0.00 / P520 [Max Fwd Speed]Units: HzDefault: 0.00Min/Max: 0.00 / P520 [Max Fwd Speed]Default: 0.00Min/Max: 0.00 / 159999.15Default: 0.00Min/Max: 0.00 / 159999.15Read-WriteData TypeRW RealRW RealRW RealRW 32-bitIntegerRW 32-bitIntegerFileGroupNameNo. Description1131 753 Adj Vltg ConfigAdjustable Voltage ConfigurationSelects input voltage phase setting.ValuesRead-WriteData TypeOptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedPhaseSettingDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = 3-Phase Operation1 = 1-Phase OperationAPPLICATIONSAdjustable Vltg1133 753 Adj Vltg SelectAdjustable Voltage Reference SelectSelects the source of the voltage reference to the drive.1134 753 Adj Vltg Ref HiAdjustable Voltage Reference HighScales the upper value of the P1133 [Adj Vltg Select] selection when the sourceis an analog input.1135 753 Adj Vltg Ref LoAdjustable Voltage Reference LowScales the lower value of the P1133 [Adj Vltg Select] selection when the source isan analog input.1136 753 Adj Vltg TrimSelAdjustable Voltage Trim SelectSelects the source of the voltage trim that is added to or subtracted from thevoltage reference.1137 753 Adj Vltg Trim HiAdjustable Voltage Trim HighScales the upper value of the P1136 [Adj Vltg TrimSel] selection when the sourceis an analog input.Default: 0Min/Max: 0 / 159999Units: %Default: 0.00Min/Max: –/+100.00 of Drive Rated VoltsUnits: %Default: 0.00Min/Max: –/+100.00 of Drive Rated VoltsDefault: 0Min/Max: 0 / 159999Units: %Default: 0.00Min/Max: –/+100.00 of Drive Rated VoltsRW 32-bitIntegerRW RealRW RealRW 32-bitIntegerRW Real<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!