Appendix ASupplemental Drive InformationSpecificationsCategory <strong>PowerFlex</strong> 755Certifications Listed to UL508C and CAN/CSA-C22.2 No. 14-05...TUVRheinlandProduct Safety..TUVRheinlandN223EPRIGOST-RRoHSEWCProduction inspectedEN 61800-5-1Bauart geprüftFunctionalSafetyType approvedIn conformity with the following European Directives:EMC Directive (2004/108/EC)Low Voltage Directive (2006/95/EC)Standards applied:EN 61800-3:2004EN 61800-5-1:2007TÜV RheinlandStandards applied:EN 61800-3:2004EN 61800-5-1:2007EN ISO 13849-1:2008EN ISO 13849-2:2003EN 61800-5-2:2007EN 61508 PARTS 1-7:2000EN 62061:2005EN 60204-1:2006Australian Communications and Media AuthorityIn conformity with the following:Radiocommunications Act: 1992Radiocommunications Standard: 2008Radiocommunications Labelling Notice: 2008Standards applied:EN 61800-3:2004Electric Power Research InstituteCertified compliant with the following standards:SEMI F47IEC 61000-4-34Russian GOST-R Certificate no.POCC US.ME92.H00040Compliant with the European "Restriction of Hazardous Substances"DirectiveCategory SpecificationProtection Drive 380/400 480V 500V 600V 690V<strong>AC</strong> Input Overvoltage Trip: 576V <strong>AC</strong> 576V <strong>AC</strong><strong>AC</strong> Input Undervoltage Trip: 250V <strong>AC</strong> 300V <strong>AC</strong>Bus Overvoltage Trip: 815V DC 815V DCBus Undervoltage Shutoff: 200V DC 200V DCNominal Bus Voltage (Full Load): 540V DC 648V DCDrive Overcurrent TripSoftware Overcurrent Trip:Hardware Overcurrent Trip:Instantaneous Current Limit:Calculated value, 105% of motor rated to 200% of drive rated105% of 3 sec. rating (158…210%)143% of 3 sec. rating (215…287%)Line transients:up to 6000 volts peak per IEEE C62.41-1991Control Logic Noise Immunity: Showering arc transients up to 1500V peakPower Ride-Thru:15 milliseconds at full loadLogic Control Ride-Thru:0.5 seconds minimum, 2 seconds typicalGround Fault Trip:Phase-to-ground on drive outputShort Circuit Trip:Phase-to-phase on drive output<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!