12.07.2015 Views

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Programming and Parameters 3-121FileGroupRead-WriteData TypeNameNo. DescriptionValues1217 755 Prof DI InvertProfile Digital Input InvertSets polarity of the digital inputs. Each bit is assigned to a move table step. Rising edge of the digital input is used when the bit is off, and falling edgeof digital input is used when the bit is on.APPLICATIONSProfilingOptionsBit 0 “Hold Step” – sets polarity of the digital input for the hold step, P1218 [DI Hold Step].Bit 1 “Abort Step” – sets polarity of the digital input for abort step, P1219 [DI Abort Step].Bit 2 “AbortProfile” – sets polarity of the digital input for abort profile, P1220 [DI Abort Profile].Bit 3 “Vel Override” – sets polarity of the digital input for velocity override, P1221 [DI Vel Override].Bit 4 “StrStepSel0” – sets polarity of the digital input for start step 1, P1222 [DI StrtStep Sel0].Bit 5 “StrStepSel1” – sets polarity of the digital input for start step 2, P1223 [DI StrtStep Sel1].Bit 6 “StrStepSel2” – sets polarity of the digital input for start step 3, P1224 [DI StrtStep Sel2].Bit 7 “StrStepSel3” – sets polarity of the digital input for start step 4, P1225 [DI StrtStep Sel3].Bit 8 “StrStepSel4” – sets polarity of the digital input for start step 5, P1226 [DI StrtStep Sel4]Bit 9 “Step 1” – sets polarity of the digital input for move step 1, P1230 [Step 1 Type].Bit 10 “Step 2” – sets polarity of the digital input for move step 2, P1240 [Step 2 Type].Bit 11 “Step 3” – sets polarity of the digital input for move step 3, P1250 [Step 3 Type].Bit 12 “Step 4” – sets polarity of the digital input for move step 4, P1260 [Step 4 Type].Bit 13 “Step 5” – sets polarity of the digital input for move step 5, P1270 [Step 5 Type].Bit 14 “Step 6” – sets polarity of the digital input for move step 6, P1280 [Step 6 Type].Bit 15 “Step 7” – sets polarity of the digital input for move step 7, P1290 [Step 7 Type].Bit 16 “Step 8” – sets polarity of the digital input for move step 8, P1300 [Step 8 Type].Bit 17 “Step 9” – sets polarity of the digital input for move step 9, P1310 [Step 9 Type].Bit 18 “Step 10” – sets polarity of the digital input for move step 10, P1320 [Step 10 Type].Bit 19 “Step 11” – sets polarity of the digital input for move step 11, P1330 [Step 11 Type].Bit 20 “Step 12” – sets polarity of the digital input for move step 12, P1340 [Step 12 Type].Bit 21 “Step 13” – sets polarity of the digital input for move step 13, P1350 [Step 13 Type].Bit 22 “Step 14” – sets polarity of the digital input for move step 14, P1360 [Step 14 Type].Bit 23 “Step 15” – sets polarity of the digital input for move step 15, P1370 [Step 15 Type].Bit 24 “Step 16” – sets polarity of the digital input for move step 16, P1380 [Step 16 Type].1218 755 DI Hold StepReservedReservedReservedReservedReservedReservedReservedStep 16Step 15Step 14Step 13Step 12Step 11Step 10Step 9Step 8Step 7Step 6Step 5Step 4Step 3Step 2Step 1StrStepSel4StrStepSel3StrStepSel2StrStepSel1StrStepSel0Vel OverrideAbortProfileAbort StepHold StepDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = TrueDigital Input Hold StepSets a digital input port for the hold step in profile/indexer control logic. The digitalinput assigned by this parameter is equivalent to P1213 [Profile Command] Bit 8“Hold Step.” Polarity of active state is defined by P1217 [Prof DI Invert] Bit 0 “HoldStep.”1219 755 DI Abort StepDigital Input Abort StepSets a digital input port for the abort step in profile/indexer control logic. Polarityof active state is defined by P1217 [Prof DI Invert] Bit 1 “Abort Step.”1220 755 DI Abort ProfileDigital Input Abort ProfileSets a digital input port for the abort profile in profile/indexer control logic. Polarityof active state is defined by P1217 [Prof DI Invert] Bit 2 “AbortProfile.”1221 755 DI Vel OverrideDigital Input Velocity ProfileSets a digital input port for the velocity override in profile/indexer control logic.The digital input assigned by this parameter is equivalent to P1213 [ProfileCommand] Bit 9 “Vel Override.” Polarity of active state is defined by P1217 [ProfDI Invert] Bit 3 “Vel Override.”Default: 0.00Min/Max: 0.00 / 159999.15Default: 0.00Min/Max: 0.00 / 159999.15Default: 0.00Min/Max: 0.00 / 159999.15Default: 0.00Min/Max: 0.00 / 159999.15RW 32-bitIntegerRW 32-bitIntegerRW 32-bitIntegerRW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!