Programming and Parameters 3-21FileGroupNameNo. Description35 Motor Ctrl ModeMotor Control ModeMotor type and motor control mode.ValuesRead-WriteData TypeDefault:Options:1 = “Induction SV”0 = “InductionVHz”1 = “Induction SV”2 = “Induct Econ”3 = “Induction FV”4 = “PM VHz”5 = “PM SV”6 = “PM FV”7 = “SyncRel VHz”8 = “SyncRel SV”9 = “Adj Voltage”RW 32-bitInteger36 Maximum VoltageMaximum VoltageThe highest voltage the drive will output.37 Maximum FreqMaximum FrequencyThe frequency the drive will output at P36 [Maximum Voltage] when a “VHz”mode is selected by P35 [Motor Ctrl Mode]. Refer to diagram for P524[Overspeed Limit].38 PWM FrequencyPulse Width Modulation FrequencyPulse Width Modulated frequency (power transistor switching frequency). Drivederating may occur with increased values.40 Mtr Options CnfgMotor Options ConfigurationConfiguration of motor control-related functions.Units: V<strong>AC</strong>Default: Based on Drive RatingMin/Max: Based on Drive RatingRW RealUnits: HzDefault: P27 [Motor NP Hertz] x 2 + 10 HzMin/Max: P27 [Motor NP Hertz] + 10 Hz / 420.00RW RealUnits: kHzDefault: Based on Drive RatingMin/Max: Based on Drive RatingRW RealMOTOR CONTROLMtr Ctrl OptionsOptionsJerk SelectReservedReservedXsistor DiagElect StabDB WhileStopPWM FreqLockAsyncPWMLockPWM Type SelRS AdaptionReflect WaveMtr Lead RevEnclsTrqProv (1)Trq ModeJogTrq ModeStopZero TrqStopDefault 1 0 0 1 1 0 0 0 1 1 1 0 0 1 1 1Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition True(1) 755 drives only.Bit 0 “Zero TrqStop” – Configures stopped condition when in torque mode. 0 = wait for zero speed before shutting off drive output, 1 = wait for zerotorque before shutting off drive output.Bit 1 “Trq ModeStop” – Configures stopping behavior when in torque mode. 0 = remain in torque mode, 1 = switch to speed modeBit 2 “Trq ModeJog” – Configures jogging behavior when in torque mode. 0 = remain in torque mode, 1 = switch to speed modeBit 3 “EnclsTrqProv” – Enables encoderless mode when using the torque prove function. 0 = Disabled, 1 = Enabled. Bits 0 and 1 of P1100 [Trq ProveCfg] must also be set to use this mode.Bit 4 “Mtr Lead Rev” – Reverses the phase rotation of the applied voltage, effectively reversing the motor leads. 0 = Not Reversed, 1 = ReversedBit 5 “Reflect Wave” – Enables reflected wave voltage protection for long motor cables. 0 = Disabled, 1 = EnabledBit 6 “RS Adaption” – Adapts for changes in motor stator resistance due to motor temperature. Active only in FV motor control mode with feedback.0 = Disabled, 1 = EnabledBit 7 “PWM Type Sel” – Configures 3 Phase / 2 Phase switching of the power devices. 0 = 3 Phase modulation with auto switchover to 2 phasemodulation. 1 = Full time 3 phase modulation (no switchover)Bit 8 “AsyncPWMLock” – Configures Synchronous / Asynchronous switching of the power devices. 0 = Automatically changes between synchronousand asynchronous. 1 = Synchronous switching only.Bit 9 “PWM FreqLock” – Configures switching frequency of the power devices while in FV motor control mode without feedback. 0 = switchingfrequency automatically reduces to 2 kHz at low speeds (best performance), 1 = switching frequency does not reduce (setting used when switchingfrequency reduction is undesirable)Bit 10 “DB WhileStop” – Enables operation of the dynamic brake transistor while the drive is stopped. 0 = Disabled, 1 = EnabledBit 11 “Elect Stab” – Enables stability control for Sensorless Vector and V/Hz motor control modes. 0 = Disabled, 1 = EnabledBit 12 “Xsistor Diag” – Enables power transistor diagnostic test at each start command. 0 = Disabled, 1 = EnabledBit 15 “Jerk Select” – Limits the rate of change to the velocity reference for improved current limiting. This setting applies only to Sensorless Vectorand V/Hz motor control modes. 0 = Disabled (0.0 second ramp time achievable), 1 = Enabled (0.0 second ramp time prevented)<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!