Programming and Parameters 3-47FileGroupNo.NameDescriptionValuesRead-WriteData TypeDRIVE CFGDrive Memory336 Reset MetersReset MetersResets selected meters to zero. The value will automatically be returned to 0.Default:Options:0 = “Ready”0 = “Ready”1 = “MWH and kWh”2 = “Elapsed Time”RW 32-bitIntegerFileGroupNo.NameDescriptionValuesRead-WriteData Type345 Start At PowerUpStart At Power UpEnables/disables a feature to issue a Start or Run command and automaticallyresume running at commanded speed after drive input power is restored.Requires a digital input configured for Run or Start and a valid start contact.Default:Options:0 = “Disabled”0 = “Disabled”1 = “Enabled”RW 32-bitInteger!ATTENTION: Equipment damage and/or personal injury may result if this parameter is used in aninappropriate application. Do not use this function without considering applicable local, national andinternational codes, standards, regulations or industry guidelines.346 PowerUp DelayPower Up DelayDefines the programmed delay time, in seconds, before a start commend isaccepted after power up.Units: SecsDefault: 0.00Min/Max: 0.00 / 10800.00RW RealDRIVE CFGStart Features347 Auto Retry FaultAutomatic Retry FaultEnables Retries Exhausted fault action.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedAttmpsExhstdDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition True348 Auto Rstrt TriesDefault: 0Automatic Restart TriesMin/Max: 0 / 9Sets the maximum number of times the drive attempts to reset a fault and restart.RW 32-bitInteger!ATTENTION: Equipment damage and/or personal injury may result if this parameter is used in aninappropriate application. Do not use this function without considering applicable local, national andinternational codes, standards, regulations or industry guidelines.349 Auto Rstrt DelayAutomatic Restart DelaySets the time between restart attempts when 348 [Auto Rstrt Tries] is set to avalue other than zero.Units: SecsDefault: 1.00Min/Max: 0.50 / 30.00RW Real<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!