12.07.2015 Views

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

87 94 5 612 0387 94 5 6132 02-4 Start UpDrive Status IndicatorsTable 2.A <strong>PowerFlex</strong> 753 Status Indicator DescriptionsName Color State DescriptionSTS Green Flashing Drive ready but not running, and no faults are present.(Status)Steady Drive running, no faults are present.Yellow Flashing Drive is not running, a type 2 (non-configurable) alarm conditionexists and the drive cannot be started.Steady Drive is not running, a type 1 (user configurable) alarm conditionexists and the drive continues to run.Red Flashing A major fault has occurred. Drive will stop. Drive cannot be starteduntil fault condition is cleared.Steady A non-resettable fault has occurred.Red /YellowFlashingAlternatelyA minor fault has occurred. When running, the drive continues to run.System is brought to a stop under system control. Fault must becleared to continue. Use parameter 950 [Minor Flt Config] to enable.If not enabled, acts like a major fault.Yellow /GreenFlashingAlternatelyWhen running, a type 1 alarm exists.Green /RedFlashingAlternatelyDrive is flash updating.Table 2.B <strong>PowerFlex</strong> 755 Status Indicator DescriptionsName Color State DescriptionSTS Green Flashing Drive ready but not running, and no faults are present.(Status)Steady Drive running, no faults are present.Yellow Flashing Drive is not running, a type 2 (non-configurable) alarm conditionexists and the drive cannot be started.Steady Drive is not running, a type 1 (user configurable) alarm conditionexists and the drive continues to run.Red Flashing A major fault has occurred. Drive will stop. Drive cannot be starteduntil fault condition is cleared.Steady A non-resettable fault has occurred.Red / Flashing A minor fault has occurred. When running, the drive continues to run.Yellow Alternately System is brought to a stop under system control. Fault must becleared to continue. Use parameter 950 [Minor Flt Config] to enable.If not enabled, acts like a major fault.Yellow / Flashing When running, a type 1 alarm exists.Green AlternatelyGreen / Flashing Drive is flash updating.Red AlternatelyENET Unlit Off Adapter and/or network is not powered, adapter is not properlyconnected to the network, or adapter needs an IP address.Red Flashing An EtherNet/IP connection has timed out.Steady Adapter failed the duplicate IP address detection test.Red / Flashing Adapter is performing a self-test.Green AlternatelyGreen Flashing Adapter is properly connected but is not communicating with anydevices on the network.Steady Adapter is properly connected and communicating on the network.LINK Unlit Off Adapter is not powered or is not transmitting on the network.Green Flashing Adapter is properly connected and transmitting data packets on thenetwork.Steady Adapter is properly connected but is not transmitting on the network.Important: The Status Indicator LEDs on the HIM cradle do not indicatethe current status of an installed Communication Adapteroption. If an optional Communication Adapter is installed, referto that option’s user manual for a description of LED locationand indication.<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!