Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Programming and Parameters 3-109Drive Applications FileFileGroupNo.NameDescriptionValuesRead-WriteData Type1065 PID CfgPID ConfigurationMain configuration of the Process PID controller.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedPercent RefAnti WindupStop ModeFdbk SqrtZero ClampRamp RefPreload IntDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True1066 PID ControlPID ControlUsed for dynamically controlling the Process PID controller.OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedPID InvErrorPID ResetPID HoldPID EnableDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = False1 = True1067 PID Ref SelPID Reference SelectSelects the source for the PID Reference. A zero sets the Reference to a fixedvalue.Default: 1070Min/Max: 0 / 159999RW 32-bitIntegerAPPLICATIONSProcess PID1068 PID Ref AnlgHiPID Reference Analog HighWhen an analog input is selected for PID Ref this sets high value of scaling.1069 PID Ref AnlgLoPID Reference Analog LowWhen an analog input is selected for PID Ref this sets low value of scaling.Units: %Default: 100.00Min/Max: –/+100.00Units: %Default: 100.00Min/Max: –/+100.00RW RealRW Real1070 PID SetpointPID SetpointProvides an internal fixed value for PID Ref when P1067 [PID Ref Sel] is set tothis parameter.Units: %Default: 0.00Min/Max: –/+100.00RW Real1071 PID Ref MultPID Reference MultiplierSets the multiplying factor which is applied to the Reference source before theReference is used.Units: %Default: 100.00Min/Max: –/+100.00RW Real1072 PID Fdbk SelPID Feedback SelectSelects the source for the PID Feedback. A zero sets the Feedback to a fixedvalue.Default: 1077Min/Max: 1 / 159999RW 32-bitInteger1073 PID Fdbk AnlgHiPID Feedback Analog HighWhen an analog input is selected for PID Feedback this sets high value ofscaling.Units: %Default: 100.00Min/Max: –/+100.00RW Real1074 PID Fdbk AnlgLoPID Feedback Analog LowUnits:Default:%0.00When an analog input is selected for PID Feedback this sets low value of scaling. Min/Max: –/+100.00RW Real1075 PID FBLoss SpSelPID Feedback Loss Speed SelectWhen an analog input is selected for PID Feedback, P1079 [PID Output Sel] isset to Speed Excl/Speed Trim, and an analog signal loss is detected, sets speedto this source.Default: 546Min/Max: 0 / 159999RW 32-bitInteger<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!