12.07.2015 Views

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

PowerFlex 750-Series AC Drives User Manual

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Programming and Parameters 3-173FileGroupNo.NameDescriptionValuesRead-WriteData Type45 FB1 IncAndSC PPRFeedback 1 Incremental and Sine Cosine Pulses Per RevolutionIndicates the Pulses Per Revolution (Encoder Lines) of the SinCos or A Quad Bencoder for the feedback 1 device.For the following selections, PPR is automatically read from the encoder:• EnDat SC• BiSS SC (not manually configured)• Hiperface SCFor the following selections, PPR has to be entered by the user:• BiSS SC, <strong>Manual</strong>ly configured• Gen SinCos• A Quad BUnits: PDRDefault: 1024Min/Max: 1 / 100000RW 32-bitInteger46 FB1 Inc CfgFeedback 1 Incremental ConfigurationConfigures Incremental Feedback for the feedback 1 device.HOST GROUPSFeedback 1OptionsReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedReservedSingle EndedReservedEdge ModeA Chan OnlyZ Chan EnblDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition TrueBit 0 “Z Chan Enbl” – When set, Channel Z is also monitored for Phase Loss. When cleared, Channel Z is ignored for Phase Loss detection.Only used if [FB1 Device Sel] = “Inc A B Z”.Bit 1 “A Chan Only” – When set, logic monitors only channel A. When clear, logic monitors both A and B.Bit 2 “Edge Mode” – When set, speed calc uses AB edge data. When clear, speed calc does not use AB edge data.Bit 4 “Single Ended” – This bit has to be set if the connected A Quad B encoder has single ended signals. For these encoders, the Phase Lossdetection is switched off.47 FB1 Inc StsFeedback 1 Incremental StatusDisplays Incremental Feedback status for the feedback 1 device.OptionsReservedReservedReservedReservedReservedReservedReservedReservedZ Not InputZ InputB Not InputB InputA Not InputA InputA Chan OnlyZ Chan EnblDefault 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 = Condition False1 = Condition TrueBit 0 “Z Chan Enbl” – Indicates that Channel Z is monitored for Phase Loss. Only used if [FB1 Device Sel] = “Inc A B Z”.Bit 1 “A Chan Only” – Indicates only A channel is monitored, B channel not used.Bit 2 “A Input” – State of encoder A input signalBit 3 “A Not Input” – State of encoder A Not input signalBit 4 “B Input” – State of encoder B input signalBit 5 “B Not Input” – State of encoder B Not input signalBit 6 “Z Input” – State of encoder Z input signalBit 7 “Z Not Input” – State of encoder Z Not input signal<strong>PowerFlex</strong> <strong>750</strong>-<strong>Series</strong> <strong>User</strong> <strong>Manual</strong> – Publication <strong>750</strong>-UM001C-EN-P – September 2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!