2.5.4 What about measurements of chemical components of <strong>PM2.5</strong>?<br />
81. Measurements of specific components of <strong>PM2.5</strong> used with<strong>in</strong> this report can<br />
have lower uncerta<strong>in</strong>ties than the mass concentration itself, especially if they<br />
are non-volatile, as they are <strong>in</strong>dependent of water content. However, specific<br />
<strong>in</strong>struments such as the MARGA at Auchencorth Moss have had ongo<strong>in</strong>g<br />
operational problems mak<strong>in</strong>g the data less reliable. Moreover, care must be<br />
taken when compar<strong>in</strong>g method-dependent quantities such as black carbon,<br />
elemental carbon and organic carbon. In some cases, specific components of<br />
PM10 have been used <strong>in</strong> this report where <strong>PM2.5</strong> data are not available, and the<br />
<strong>in</strong>clusion of the coarse size fraction needs to be taken <strong>in</strong>to consideration.<br />
2.6 Recommendations<br />
Measur<strong>in</strong>g <strong>PM2.5</strong> and its components<br />
82. Measurements of <strong>PM2.5</strong> <strong>in</strong> the UK depend heavily on the FDMS<br />
<strong>in</strong>strument, which has a relatively short track record <strong>in</strong> monitor<strong>in</strong>g<br />
networks. AQEG recommends that issues <strong>in</strong>clud<strong>in</strong>g long-term reliability,<br />
dryer performance and the handl<strong>in</strong>g of semi-volatile components<br />
are further <strong>in</strong>vestigated with the aim of better understand<strong>in</strong>g the<br />
measurement results and of improv<strong>in</strong>g data capture and measurement<br />
uncerta<strong>in</strong>ty.<br />
83. At present the measurement of <strong>PM2.5</strong> rema<strong>in</strong>s a challenge, with<br />
current measurements fall<strong>in</strong>g below the requirements of the <strong>Air</strong> Quality<br />
Directive. AQEG recommends a focused work<strong>in</strong>g <strong>group</strong> is assembled<br />
to address the achievement of Directive requirements us<strong>in</strong>g current<br />
methods.<br />