In Online mode the PC-card serves as the data source. It registers CAN messages<br />
on the bus and passes them on to <strong>CANoe</strong>.<br />
Moreover, some of the supported PC-cards also provide additional information such<br />
as the detection of Error and Overload flags, the values of error counters, the bus<br />
load and external trigger signals.<br />
The card is initialized at the start of an online measurement. You can configure the<br />
necessary parameters from the main menu under Configuration or from the popup<br />
menu of the simulation setup's card icon. The connection to the measurement setup<br />
is symbolized by the >> symbol on the left in the measurement setup window.<br />
In the evaluation branches of the measurement setup, data are passed from left to<br />
right to the measurement setup's evaluation blocks, where they can be visualized<br />
and analyzed with various functions.<br />
Filters or user-defined analysis programs can be inserted in the data flow diagram<br />
before the evaluation blocks. As a result, the data flow can be configured in many<br />
ways to suit the particular task.<br />
Each evaluation block has a measurement window in which the data arriving in the<br />
block are displayed. The functions of all measurement windows are described in detail<br />
in the sections below. Only the logging block is not assigned its own window. Instead,<br />
a log file is assigned to it for the purpose of logging bus data traffic and then<br />
studying it "offline" (cf. section 2.7.2).<br />
Located between the function blocks are insertion points (hotspots), at which blocks<br />
can be inserted for to manipulate the data flow (Filter, replay, generator block, CAPL<br />
program block with user-definable functions). Before and after the block inserted in<br />
this manner, new hotspots appear, so that additional blocks can be inserted. The data<br />
flow can also be broken at the hotspots. You will find a description of all insertable<br />
function blocks in section 4.<br />
Figure 52 shows a possible <strong>CANoe</strong> configuration in Online mode 3 , in which multiple<br />
network nodes are provided in the simulation setup. A filter is inserted in the trace<br />
branch, graphics branch and in the data branch so that only certain messages will be<br />
displayed. The statistics branch and the bus statistics branch each receive all data,<br />
while the logging branch is broken.<br />
Note: The data flow in the measurement setup is always directional. It runs from<br />
the left, starting at the connection symbol (connection to the simulation<br />
setup) to the evaluation windows on the right.<br />
3.2.2 Configuration of the Measurement Setup<br />
Besides such functions as loading and saving configurations or associating CAN databases,<br />
which you call directly from items in the main menu, the data flow diagram<br />
and the function blocks in the measurement setup window are used primarily in the<br />
configuration of <strong>CANoe</strong>.<br />
3 Data flow and functions in Online and Offline modes only differ in the data source and in the transmit<br />
block. Refer to section 2.7.4 for a description of Offline mode.<br />
© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1