09.01.2013 Views

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

88<br />

In Online mode the PC-card serves as the data source. It registers CAN messages<br />

on the bus and passes them on to <strong>CANoe</strong>.<br />

Moreover, some of the supported PC-cards also provide additional information such<br />

as the detection of Error and Overload flags, the values of error counters, the bus<br />

load and external trigger signals.<br />

The card is initialized at the start of an online measurement. You can configure the<br />

necessary parameters from the main menu under Configuration or from the popup<br />

menu of the simulation setup's card icon. The connection to the measurement setup<br />

is symbolized by the >> symbol on the left in the measurement setup window.<br />

In the evaluation branches of the measurement setup, data are passed from left to<br />

right to the measurement setup's evaluation blocks, where they can be visualized<br />

and analyzed with various functions.<br />

Filters or user-defined analysis programs can be inserted in the data flow diagram<br />

before the evaluation blocks. As a result, the data flow can be configured in many<br />

ways to suit the particular task.<br />

Each evaluation block has a measurement window in which the data arriving in the<br />

block are displayed. The functions of all measurement windows are described in detail<br />

in the sections below. Only the logging block is not assigned its own window. Instead,<br />

a log file is assigned to it for the purpose of logging bus data traffic and then<br />

studying it "offline" (cf. section 2.7.2).<br />

Located between the function blocks are insertion points (hotspots), at which blocks<br />

can be inserted for to manipulate the data flow (Filter, replay, generator block, CAPL<br />

program block with user-definable functions). Before and after the block inserted in<br />

this manner, new hotspots appear, so that additional blocks can be inserted. The data<br />

flow can also be broken at the hotspots. You will find a description of all insertable<br />

function blocks in section 4.<br />

Figure 52 shows a possible <strong>CANoe</strong> configuration in Online mode 3 , in which multiple<br />

network nodes are provided in the simulation setup. A filter is inserted in the trace<br />

branch, graphics branch and in the data branch so that only certain messages will be<br />

displayed. The statistics branch and the bus statistics branch each receive all data,<br />

while the logging branch is broken.<br />

Note: The data flow in the measurement setup is always directional. It runs from<br />

the left, starting at the connection symbol (connection to the simulation<br />

setup) to the evaluation windows on the right.<br />

3.2.2 Configuration of the Measurement Setup<br />

Besides such functions as loading and saving configurations or associating CAN databases,<br />

which you call directly from items in the main menu, the data flow diagram<br />

and the function blocks in the measurement setup window are used primarily in the<br />

configuration of <strong>CANoe</strong>.<br />

3 Data flow and functions in Online and Offline modes only differ in the data source and in the transmit<br />

block. Refer to section 2.7.4 for a description of Offline mode.<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!