09.01.2013 Views

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

CANoe DENoe - KEMT FEI TUKE

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Furthermore, the panel configuration dialog also offers you the option of selecting<br />

certain panels which should remain permanently open, i.e. should not be influenced<br />

by the actions of panel control. Simply enter the particular panels in the<br />

list of permanently opened panels. On the one hand, these may include the<br />

control panels themselves, which should not be closed. Of course, on the other<br />

hand you can also enter important display and control panels here which must<br />

constantly remain open.<br />

In the panel configuration dialog you can also enter panel groups for the two<br />

predefined events Measurement start and Loading/Measurement stop. Panel<br />

control opens the particular panel when the event occurs, just as though you<br />

had pressed the particular configured panel control pushbutton. Here you can<br />

also decide whether opened panels which do not belong to these events should<br />

be closed or not.<br />

Panel Control in <strong>CANoe</strong><br />

With Panel Control under the main menu item Panel you can arrange and position<br />

any panel group you want and save them under a defined name.<br />

In this dialog Panel Control you can also open and close the defined panel<br />

groups and single panels.<br />

Note, that only one panel group and/or any single panel can be opened at a<br />

time.<br />

2.6.5 Configuring the Panel Control for Small Models<br />

When small models are set up, it is often unnecessary to implement the mechanisms<br />

of panel control. Here it is advisable to first enter all necessary panels into the list of<br />

permanently opened panels. You should always use the list of panels to be opened<br />

after the start of measurement if there are certain panels which you only wish to use<br />

during the measurement. You can decide in the configuration dialog whether these<br />

panels should automatically be closed again at the end of a measurement.<br />

2.7 Logging and Evaluation of Measurement Files<br />

<strong>CANoe</strong> offers you the option of saving the CAN data traffic in a log file, so that you<br />

can evaluate it later in Offline mode.<br />

Logging blocks are provided to you for this purpose. The task of a logging block is to<br />

store data arriving at its input to a file. You can configure the log file in the measurement<br />

setup by the file icon at the far right in the logging branch.<br />

Each logging block is equipped with user-friendly triggering to reduce the amount of<br />

data as much as possible even before acquisition. This permits the formulation of a<br />

trigger condition, and data are only saved near the time of the trigger. During each<br />

measurement multiple triggers can be initiated for various events, whereby the user<br />

can prescribe pre-trigger and post-trigger times. The trigger condition is userprogrammable.<br />

You can configure triggering in the measurement setup via the<br />

Logging function block.<br />

<strong>CANoe</strong> has an Offline mode for analyzing log files. In contrast to Online mode the<br />

data source here is a file, e.g. a file created by logging in Online mode. All measure-<br />

© Vector Informatik GmbH <strong>CANoe</strong>/<strong>DENoe</strong> Manual Version 4.1.1<br />

59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!